Evaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study
نویسندگان
چکیده مقاله:
Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in optimization of linac head materials. The aim of this study was to calculate electron contamination of Varian linac.Materials and Method: The 6MV photon beam of Varian (2100 C/D) linac was simulated by Monte Carlo code, MCNPX, based on its company’s instructions. The validation was done by comparing the calculated depth dose and profiles of simulation with dosimetry measurements in a water phantom (error less than 2%). The Percentage Depth Dose (PDDs), profiles and contamination electron energy spectrum were calculated for different therapeutic field sizes (5×5 to 40×40 cm2) for both linacs. Results: The dose of electron contamination was observed to rise with increase in field size. The contribution of the secondary contamination electrons on the surface dose was 6% for 5×5 cm2 to 27% for 40×40 cm2, respectively. Conclusion: Based on the results, the effect of electron contamination on patient surface dose cannot be ignored, so the knowledge of the electron contamination is important in clinical dosimetry. It must be calculated for each machine and considered in Treatment Planning Systems.Â
منابع مشابه
evaluation of electron contamination in cancer treatment with megavoltage photon beams: monte carlo study
background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy. monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...
متن کاملMonte Carlo estimation of electron contamination in a 18 MV clinical photon beam
Background: The electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. The detailed characteristics of contaminant electrons are presented for different field sizes and cases. Materials and Methods: The Monte Carlo code, MCNPX, has been used to simulate 18 MV photon beam from a Varian Linac-2300 accelerator. All dose measurements were car...
متن کاملRadiation dose enhancement in skin therapy with nanoparticle addition: A Monte Carlo study on kilovoltage photon and megavoltage electron beams
AIM To investigated the dose enhancement due to the incorporation of nanoparticles in skin therapy using the kilovoltage (kV) photon and megavoltage (MV) electron beams. Monte Carlo simulations were used to predict the dose enhancement when different types and concentrations of nanoparticles were added to skin target layers of varying thickness. METHODS Clinical kV photon beams (105 and 220 k...
متن کاملAn assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method
Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...
متن کاملMonte Carlo Study of Unflattened Photon Beams Shaped by Multileaf Collimator
Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 1
صفحات -
تاریخ انتشار 2015-03-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023