Evaluation of changes in excision cavity volume during whole breast irradiation using secondary CT image

نویسندگان

  • A.R. Nikoofar Parsa Radiotherapy Center, Pars Hospital, Tehran, Iran
  • G.H. Hoseinzadeh Tehran University Medical Sciences, Tehran Iran
  • Z. Falahatpour Medical Radiation Engineering of Faculty of Shahid Beheshti University, Tehran, Iran
چکیده مقاله:

Background: The aim of this study was to evaluate the reduction in excision cavity volume (ECV) during the whole breast radiotherapy (WBRT). The delineating of reduced cavity volume on secondary CT (computed tomography) might decrease the field size of boost plan. Materials and Methods: Twenty patients were treated having breast conservative surgery. At first, primary CT simulation (CT-1) was done prior to WBRT. Treatment planning was performed by a 3D treatment planning system. A CT-2 was performed after WBRT. Then the excision cavity was contoured on CT-1 and CT-2 for each patient. Boost irradiation was planned on both ECV-1 and ECV-2. Results: In Comparison of CT-1 and CT-2: The contoured volumes for ECV-1 and ECV-2 were on average of 42.9 cm3and 23.4 cm3, respectively (p< 0.002). The ECV-2 was reduced in 85% of the patients. Patients with ECV-1 greater than the mean value of ECV-1 (ECV-1> 35.5 cm3) had more reduction in ECV-2 than patient with ECV-1 smaller than the mean value (p < 0.000). The volume of normal breast tissue on CT-2 was decreased from the volume of CT-1 (p< 0.03). Conclusion: A significant reduction in excision cavity volume was shown during WBRT. This volume reduction made smaller sizes of boost field and remaining breast received lower doses. The reduction was more significant in patient with primary large ECV. The Secondary CT for boost planning is suggested for patients with larger cavities after WBRT.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

evaluation of changes in excision cavity volume during whole breast irradiation using secondary ct image

background: the aim of this study was to evaluate the reduction in excision cavity volume (ecv) during the whole breast radiotherapy (wbrt). the delineating of reduced cavity volume on secondary ct (computed tomography) might decrease the field size of boost plan. materials and methods: twenty patients were treated having breast conservative surgery. at first, primary ct simulation (ct-1) was d...

متن کامل

Volumetric changes in the lumpectomy cavity during whole breast irradiation after breast conserving surgery

PURPOSE This study was performed to evaluate the change in the lumpectomy cavity volumes before and after whole breast radiation therapy (WBRT) and to identify factors associated with the change of volume. MATERIALS AND METHODS From September 2009 to April 2010, the computed tomography (CT) simulation data from 70 patients obtained before and after WBRT was evaluated. The lumpectomy cavity vo...

متن کامل

Evaluation of regional nodes irradiation during breast cancer radiotherapy

Background: The purpose of this study was to evaluate nodal irradiation with conventional three-field's technique. Materials and Methods: Fifty patients with breast cancer were enrolled in this study. Computed tomography scans in the supine treatment position were imported into a treatment planning system. Levels I-III axillary and supraclavicular nodes were identified and their depths to the a...

متن کامل

Dose-volume Analysis of Heart and Lung during 3D Planning of Tangential Breast Cancer Irradiation

Introduction: Breast cancer is becoming more frequently diagnosed at early stages with improved long-term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Materials and Methods: Twenty...

متن کامل

Radiobiological and physical effects of patient setup errors during whole breast irradiation

Background: The dose-related effects of patient setup errors on bio-physical indices were evaluated for the conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques (WBI). Materials and Methods: The treatment plans of 10 patients receiving left WBI were retrospectively selected for evaluation. The bio-physical effects of dose variations were evaluated by shifting the...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 12  شماره None

صفحات  243- 248

تاریخ انتشار 2014-07

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023