Estimating the cancer risk and mortalities induced by routine digital radiography examinations on patient of different ages in Mazandaran province
نویسندگان
چکیده مقاله:
Background: The aim of this study was to estimate the cancer risks and mortalities of different types induced by routine examinations of digital radiography for one year in Mazandaran province, Iran. Materials and methods: Radiation parameters and calculated entrance skin dose (ESD) values of 13 digital radiographic examinations were collected from 2340 patients at 18 high-patient-load radiography centers. Organ mean doses were estimated based on the collected parameters applying PCXMC software. The BEIR VII-Phase 2 model was used to calculate the induced cancer risks and mortalities of various cancer types at different ages. Results: The average ± standard deviation (SD) lifetime risks (incidence probability in 100,000 people) induced by radiations from radiography examinations for one year was 51.29±4.73 and 99.62±7.36 for new-born males and females, respectively. The lifetime cancer risk decreased with age and reached 3.77±0.62 and 4.88±0.07 for 80-year men and women, respectively. The average lifetime risks of mortality due to cancers induced by annual radiographies were obtained at 14.18±1.62 and 22.83±2.55 for new-born males and females, respectively. This risk reduced with age and was reached 1.97±0.27 and 2.45±0.38 for men and women at the age of 80 years, respectively. Conclusion: Our results showed that there are low but significant risks of cancer incidence for patients undergoing digital radiography, which included a large percentage of the population in Mazandaran province, especially for children and newborns. Therefore, further efforts like appropriate patient setup and beam geometry should be carried out to decrease patient doses.
منابع مشابه
the study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region
چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...
15 صفحه اولLocal-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran
Background:The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate. Â Objective: The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the...
متن کاملthe effect of aqueous extract of garlic on formalin-induced pain in male rats
چکیده اثر عصاره آبی سیر بر درد ناشی از آزمون فرمالین در موش صحرایی نر به کوشش نرگس اسکندری روزبهانی زمینه و هدف: گیاه سیر از خانواده لیلیاسه و گونهallium sativum بومی آسیای میانه بوده و از دوران ،باستان تاکنون به خواص درمانی متفاوت آن مثل: کاهندگی قندخون، کلسترول خون، فشار خون، اثرات مفیدآن بر دستگاه قلبی عروقی و بیماریهای انعقادی خون، اثرات آنتی اکسیداتیو، درمان بیماریهای تنفسی وگوارشی، ا...
15 صفحه اولLocal-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran
BACKGROUND The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate. OBIECTIVE The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the ...
متن کاملPatient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...
متن کاملthe effect of task cognitive complexity and time limit on the performance of the learners with different proficiency levels in second language writing skill
this study investigated the effects of manipulating the cognitive complexity of tasks along +/- few elements and the time limits on l2 learners writing performance. to conduct the study, 60 iranian efl learners with two levels of proficiency, low and high intermediate, were selected and assigned to three groups based on the time devoted to task completion. the participants performed both a simp...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 18 شماره 4
صفحات 875- 884
تاریخ انتشار 2020-10
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023