Estimating average glandular dose in routine mammography screening using neural network

نویسندگان

چکیده مقاله:

Given the extensive use of common mammography tests for screening and diagnosis of breast cancer, there are concerns over the increased dose absorbed by the patient due to the sensitivity of the breast tissue. Thus, knowing the Mean Glandular Dose (MGD) before radiation to the patient through its estimation can be helpful. For this reason, the MultiLayer Perceptron (MLP) neural network model was trained with Levenberg-Marquardt (LM) backpropagation training algorithm and the Entrance Surface Air Kerma (ESAK) was estimated. After running the program, it was found that 35 neurons is the most optimal value, offering a regression coefficient of 95.7%, where the Mean Squared Error (MSE) for all data was 0.437 mGy, accounting for 4.8% of the range of output changes, representing a prediction with 95.2% accuracy in the present research. In comparison with the Monte-Carlo simulation method, it enjoys a desirable accuracy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Average Glandular Dose and Entrance Surface Dose in Mammography

In general, dose evaluation for mammography uses average glandular dose (AGD). In mammography, entrance surface dose (ESD) is high, which is well known, but actual clinical data of ESD are not reported so much. This study investigated AGD and ESD for patients whose doses were estimated from 200 mammography examinations using European Organization for Quality-Assured Breast Screening and Diagnos...

متن کامل

Quality Assurance and Average Glandular dose Measurement in Mammography Units

To ensure the safe operation of mammography units, acceptance tests and quality assurance (QA) protocols have been developed by the American Association of Physicists in Medicine (AAPM), Engineers Registration Board, and International Atomic Energy Agency. Eight mammography units manufactured by five different manufacturers located in hospitals in our region were investigated following the AAPM...

متن کامل

Assessing Image Quality and Estimating the Glandular Average Dose in Some Mammography Labs

Mammography is the safest method of detecting breast cancer but, at the same time, the most exacting radiological examination which implies getting high quality images and a minimum dose per breast. The present study was carried out in six mammography laboratories, from which only one has partially implemented a programme of quality control. There were evaluated the phantom image, film contrast...

متن کامل

Determination of Average Glandular Dose in Mammography for Rh-Rh Mammogram Using Sobol-Wu Parameters in FORTRAN Code

Introduction: To write a computational program to calculate the average glandular dose in Mammography with Rh-Rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. Materials and Methods: In this research, the Sobol-Wu parameters are used to write a FORTRAN code for glandular dose calculation in Rh-Rh target-filter mammograms. The code ...

متن کامل

Evaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation

Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...

متن کامل

Assessment of mean glandular dose in mammography.

The routine assessment of patient dose in the National Health Service Breast Screening Programme is performed as part of the quality assurance protocol recommended by the Institute of Physical Sciences in Medicine. The mean glandular dose to a standard breast is deduced from measurement of the air kerma at the entrance surface of a 4 cm Perspex phantom by applying a series of conversion factors...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  155- 162

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023