Effect of different torques on dentinal crack formation following canal preparation using neoniti rotary system
نویسندگان
چکیده مقاله:
Introduction: The aim of this study was to determine the incidence of dentinal cracks in the mesial root of maxillary molar during canal preparation using Neoniti system in different torque settings. Materials &Methods: In this in-vitro study, 60 maxillary molars extracted for various reasons were selected. The teeth were divided into 4 groups: one group(n=15) without preparation was considered as a control group (unprepared control group), the other 3 groups prepared with rotary neoniti system: group with standard torque (1.5 N/CM2)(n=15), group with high torque (2N/CM2)(n=15), and group with low torque (1N /CM2)(n=15). After a canal preparation procedure, the teeth were horizontally sectioned at 3, 6 and 9 mm from the apex. All sections were examined for determining the presence of cracks using a stereomicroscope. Data were analyzed using chi-square test. Results: There was no crack in the control group. The number of cracks was significantly higher in the high-torque group (80%) than standard- and low-torque groups (20%, 26.7%, respectively) (p<0.001). However, no significant difference was found between the standard-torque group and low-torque group (p<0.001). Conclusion: According to this study result, to avoid crack formation in higher torques using motors with torque control option is suggested.
منابع مشابه
Effect of different nickel-titanium rotary files on dentinal crack formation during retreatment procedure
Background. The aim of this study was to compare the dentinal defects caused by Reciproc, TF Adaptive and ProTaper Next NiTi rotary file systems during the retreatment procedure. Methods. A total of 150 mandibular incisors with straight and single root canals were included in the present study. All the root canals were prepared up to an apical diameter 0.40 mm using stainless steel files. Thirt...
متن کاملThe ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation.
The purpose of this study was to compare the incidence of dentinal defects (fractures and craze lines) after canal preparation with different nickel-titanium rotary files. Two hundred sixty mandibular premolars were selected. Forty teeth were left unprepared (n = 40). The other teeth were prepared either with manual Flexofiles (n = 20) or with different rotary files systems: ProTaper (Dentsply-...
متن کاملcomparison of dentinal crack formation with reciproc, mtwo and protaper root canal preparation systems
conclusions regarding the study limitations, dentinal cracks were observed in all files and distances from the apex. although there was more crack incidence in protaper files, no significant differences were noted regarding the studied systems and sections from the apex. materials and methods in an experimental in vitro trial, 80 maxillary and mandibular first molars were selected and their cro...
متن کاملIn-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation
Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having ...
متن کاملIncidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation.
INTRODUCTION The purpose of this study was to evaluate the incidence of dentinal defects after root canal preparation with reciprocating instruments (Reciproc and WaveOne) and rotary instruments. METHODS One hundred human central mandibular incisors were randomly assigned to 5 groups (n = 20 teeth per group). The root canals were instrumented by using the reciprocating single-file systems Rec...
متن کاملIncidence of Dentinal Crack after Root Canal Preparation by ProTaper Universal, Neolix and SafeSider Systems
Introduction This study aimed to compare the incidence of dentinal crack formation by instrumentation with ProTaper Universal system (rotary, multi-file system), SafeSider (reciprocation movement, multi-file system) and Neolix (rotary, single-file system). Methods and Materials In this in vitro study, 60 freshly extracted mandibular first molars were randomly divided into three experimental g...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 7 شماره None
صفحات 8- 13
تاریخ انتشار 2018-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023