Dosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code
نویسندگان
چکیده مقاله:
Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are estimated according to TG-43U1 protocol in the water phantom as reference medium while the attenuation coefficient of the sources in the water phantom is different from that of different tissues. The purpose of this study is to investigate the effects of the fat phantom materials on the TG-43U1 dosimetery parameters of the I-125 brachytherapy source using GATE 8.0 Monte Carlo code. Materials and Methods: In this work, we used GATE_v8.0 (Geant4 Application for Emission Tomography) to calculate of dosimetric parameters of the I-125 brachytherapy source model 2301. At first, validation of the GATE platform was performed by some criteria such as dose rate constant, radial dose function, 2D anisotropy function inside liquid water according to the AAPM TG-43. Then, the Monte Carlo simulated dosimetric parameters of the 2301 I-125 were calculated in fat phantom. The TG-43 dosimetry parameters of the brachytherapy source were compared with those of the fat phantom. Results: Dosimetric parameters of simulated I-125 brachytherapy capsule show good consistency compared with the other study of the Monte Carlo simulation of I-125 source. The maximum deviation was about 9%. The maximum relative deviation of radial dose function of the fat tissue compared with water medium were about 13% at distances below 1cm. These differences increased, when the distance from the source increased. At the distance of 5cm from the source, it approximately reached to 55.67%. The maximum relative deviation of the anisotropy parameter of the fat phantom was observed about 6.7% compared with the water phantom. Conclusion: There was a good agreement between the results of this work and other study in calculation of dosimetric parameters of brachytherapy I-125 (model 2301) brachytherapy base on the recommendations of TG-43U1 protocole, using GATE Monte Carlo simulation method. Acquired results show that the obtained data can be used to develop GATE code for treatment plan of brachytherapy I- 125 brachytherapy source. Furthermore, In the clinical application of the I-125 brachytherapy source, which is contracted in the treatment of the adjacent tumors to the fat tissues, the correction factors of the fat tissues must be applied after dosimetric parameters calculation in water phantoms in the treatment planning to estimate accurate results for brachytherapy treatment planning.
منابع مشابه
Estimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code
Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...
متن کاملExperimental determination of the Task Group-43 dosimetric parameters of the new I25.S17plus (125)I brachytherapy source.
PURPOSE To present experimental dosimetry results for the new IsoSeed I25.S17plus (125)I brachytherapy source, in fulfillment of the American Association of Physicists in Medicine recommendation for, at least one, experimental dosimetry characterization of new low-energy seeds before their clinical implementation. METHODS AND MATERIALS A batch of 100 LiF thermoluminescent dosimeter (TLD)-100 ...
متن کاملDosimetric parameters of three new solid core I‐125 brachytherapy sources
Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of 125I has been adsorbed, encased within a titanium housing. The PharmaSeed BT-125 source manufactured by Syncor is available in silver or palladium co...
متن کاملInvestigation of the Effects of Tissue Inhomogeneities on the Dosimetric Parameters of a Cs-137 Brachytherapy Source using the MCNP4C Code
Introduction: Brachytherapy is the use of small encapsulated radioactive sources in close vicinity of tumors. Various methods are used to obtain the dose distribution around brachytherapy sources. TG-43 is a dosimetry protocol proposed by the AAPM for determining dose distributions around brachytherapy sources. The goal of this study is to update this protocol for presence of bone and air inhom...
متن کاملA Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation
Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...
متن کاملDetermination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source
Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 295- 295
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023