Dosimetric Characteristics of Transparent Bolus for External Beam Radiotherapy

نویسندگان

  • Jeevan Ram R.K Dept.of Medical Physics, Bharathidasan University, Tiruchirapalli, India
  • SenthilKumar S Dept. of Radiotherapy, Madurai Medical College & Govt. Rajaji Hospital, Madurai, India.
چکیده مقاله:

Introduction: In radiotherapy, the bolus is often used while treating the tumor under the uneven surfaces of the patients for correcting the anatomical irregularities and increasing skin dose. Wet cotton and wet gauze are still used in developing countries, since the use of wet cotton and wet gauze has certain disadvantages, there is a need for transparent bolus which should be similar to a universally accepted bolus in terms of properties with a lower cost (50% less expensive). Material and Methods: The present study was conducted to investigate the characteristics of transparent bolus (Senflab) material, such as transmission factor, percentage depth dose (PDD), stability over time and high dose, homogeneity and transparency using 6 and 15 MV photons beam and 12, 15, and 18 MeV electrons beam. Moreover, the new bolus material was compared with those of the commercially available Superflab and RW3 slab. Results: The percentage difference in the transmission factor of Senflab was less than ±1.9%, compared with Superflab and RW3. For PDD, the percentage difference was ±2.88% and ±1.26% for photons and electron beams, respectively. The performance of bolus remained constant both physically and dosimetrically after higher dose exposure. The percentage standard deviation was 0.0002% for a period of one month, and 0.0003% for the homogeneity. The transparency of the bolus material was good enough to display the set radiation treatment field. Conclusion: This study shows the suitability of the new bolus for routine use in radiotherapy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric assessment of brass mesh bolus for postmastectomy photon radiotherapy

Brass mesh bolus has been shown to be an acceptable substitute for tissue-equivalent bolus to increase superficial dose for chest wall tangent photon radiotherapy. This work investigated the increase in surface dose, the change in the dose at depth, and the safety implications of higher energy photon beams when using brass mesh bolus for postmastectomy chest wall radiotherapy. A photon tangent ...

متن کامل

Consent to external-beam radiotherapy.

Canadian law, and the physician's code of ethics, requires that informed consent be obtained before any medical act is performed. However, there are no rules about how consent is to be obtained and by whom, and how that consent is to be documented.In April 2008, we asked the heads of all Canadian radiation oncology departments to tell us whether their centre uses a written consent form for exte...

متن کامل

Hypofractionated External-Beam Radiotherapy for Prostate Cancer

There are radiobiological rationales supporting hypofractionated radiotherapy for prostate cancer. The recent advancements in treatment planning and delivery allow sophisticated radiation treatments to take advantage of the differences in radiobiology of prostate cancer and the surrounding normal tissues. The preliminary results from clinical studies indicate that abbreviated fractionation prog...

متن کامل

Treatment Machines for External Beam Radiotherapy

Since the inception of radiotherapy soon after the discovery of X rays by Roentgen in 1895, the technology of X ray production has first been aimed towards ever higher photon and electron beam energies and intensities, and more recently towards computerization and intensity modulated beam delivery. During the first 50 years of radiotherapy the technological progress was relatively slow and main...

متن کامل

Comparing the dosimetric characteristics of the electron beam from dedicated intraoperative and conventional radiotherapy accelerators

The specific design of the mobile dedicated intraoperative radiotherapy (IORT) accelerators and different electron beam collimation system can change the dosimetric characteristics of electron beam with respect to the conventional accelerators. The aim of this study is to measure and compare the dosimetric characteristics of electron beam produced by intraoperative and conventional radiotherapy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 6

صفحات  410- 415

تاریخ انتشار 2019-11-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023