DMOF-1 Assessment and Preparation to Electrochemically Determine Hydrazine in Different Water Samples
نویسندگان
چکیده مقاله:
Hydrazine has been identified as a carcinogenic mutagenic, hepatotoxic, and neurotoxin material. A metal-organic framework with tetragonal symmetry, DMOF-1 (Zn2(bdc)2dabco) was synthesized by a versatile and facile technique, followed by its efficient development and validation as hydrazine electrochemical sensor. Differential pulse voltammetry (DPV), linear sweep voltammetry (LSV), and cyclic voltammetry (CV) techniques were used as diagnostic techniques. In this study, scanning electron microscopy (SEM) and x-ray diffraction (XRD) were used to characterize the MOF. In the electro-oxidation of hydrazine, there was a highly catalytic activity shown by the modified electrode. In addition, there was a greater signal response, compared to the unmodified electrode, which was primarily because DMOF-1 offered the establishment of large active surface area. Also, the detection limit for hydrazine, linear range, and sensor sensitivity were reported to be 0.02 µM, 0.09-400.0 µM, and 0.0863 µA/µM-1, respectively. Ultimately, the amplified sensor was able to properly analyze hydrazine in different samples of water.
منابع مشابه
Developing Preparation Methods for Biological Samples to Determine Trace Amounts of Heavy Metals: A Review Study
Introduction: Perpetration of samples is one of the most important stages needed for trace residue analysis of biological specimens when human exposure assessment is required. The samples preparation process makes the analyte get more purified and enriched as well as more compatible to the analysis instrument systems. The present study has concentrated on a systematic review of different articl...
متن کاملLifetime risk assessment of Radium-226 in drinking water samples
Background: One of the most significant radionuclides in natural drinking waters is 226Ra and its decay products. It is potential of health problems, including cancer risk. In this study, the effect of 226Ra concentration in 28 drinking water samples collected from the North Guilan province was investigated. Materials and Methods: The activity concentrations of 226Ra were measured by using of r...
متن کاملPreconcentration and Speciation of Chromium Using Dispersive Liquid-Liquid Microextraction; Application to Milk and Different Water Samples
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) was developed for determination and speciation of trace amounts of chromium (Cr) by flame atomic absorption spectrometry (FAAS). In the proposed approach, chloroform and methanol were used as extraction and dispersive solvents. A new Schiff's base ligand, bis(2-methoxy benzaldehyde) ethylene d...
متن کاملOptimization Method to Determine Gross Alpha-Beta in Water Samples Using Liquid Scintillation Counter
Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because of its simplicity and low associated cost comparison with other techniques. This paper discusses a new approach to the monitoring of gross alpha and gross beta activities in water...
متن کاملSimple Electrochemical Determination of Hydrazine in Water
Hydrazine in water samples is determined by constant current chronopotentiometry in porous carbon electrodes. Hydrazine in alkaline solutions is oxidised to nitrogen in the pores of the electrode by constant current. Two types of electrodes made of reticulated vitreous carbon (RVC) were used, one fabricated from crushed RVC particles, the other with the original RVC material of 100 ppi porosity...
متن کاملComparison of different water-miscible solvents for the preparation of plasma and urine samples in metabolic profiling studies.
The Lowry method and a capillary electrophoresis method were used to analyse protein residues in the supernatant after solvent deproteination of plasma. Acetonitrile and acetone were much more effective than methanol and ethanol at reducing the levels of proteins in plasma. The ability of different solvents to decrease levels of phospholipids in plasma samples was assessed using electrospray io...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 7 شماره 2
صفحات 151- 160
تاریخ انتشار 2020-04-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023