Dimensional changes of three-unit implant-supported zirconia frameworks from scanning to sintering

نویسندگان

  • Alikhasi, Marzieh Associate Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran; Member of Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
  • Ameri, Narges Assistant Professor, Department of Prosthodontics, School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, Iran
  • Nejati, Mohammadreza Nano Robotics Laboratory, Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
  • Shamshiri, Ahmad Reza Assistant Professor, Department of Epidemiology and Statistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
  • Siadat, Hakimeh Associate Professor, Dental Research Center, Dentistry Research Institute, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Background and Aims: Passive fitness of implant frameworks are important factors for long-term success of dental implant restorations. The aim of this in vitro study was to evaluate the dimensional changes of implant supported zirconia frameworks fabricated by Zirkonzahn CAD/CAM system during fabrication stages. Materials and Methods: The master model of 3-unit FDP was made of two implant abutments. The master model was scanned 12 times and data were saved as STL files (scanning groups). Using semi-sintered zirconia, 12 real-size frameworks (milling groups) and 12 enlarged frameworks which were then sintered (sintering group) were made in this system. Dimensions of master model and specimens of each stage were measured. The dimensional changes in respect to master model were calculated. Data were analyzed using Repeated measures ANOVA, independent t-test, and paired sample t-test at α=0.05 of significance. Results: The milling stage showed greater dimensional changes comparing to the other stages (P<0.05). At all stages, the dimensional changes of premolar abutment height were greater than canine (P<0.001). Conclusion: Within the limitations of this study, the results suggested that the fabrication stages and size of abutments had significant effects on the dimensional changes of zirconia frameworks.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress distribution on a three-unit implant-supported zirconia framework. A 3D finite element analysis and fatigue test.

PURPOSE The purpose of this study was to investigate, by finite element analysis (FEA) and fatigue analysis, the influence of different loading conditions on the stress distribution in a 3-unit implant-supported Y-TZP fixed partial denture (FPD). MATERIAL AND METHODS A three-dimensional FEM model was developed. The materials used in this study were assumed to be linearly elastic, homogeneous ...

متن کامل

Effect of sintering on the marginal and internal fit of CAD/CAM-fabricated zirconia frameworks.

The aim of this study was to investigate the effect of post-machining sintering on marginal and internal fit of CAD/CAM-fabricated zirconia frameworks. Single crown copings (A: abutment), three-unit bridge frameworks (APA, P: pontic), four-unit bridge frameworks (APPA), and five-unit bridge frameworks (A1P1A2P2A3) were fabricated with raw-stage zirconia blanks using a commercial CAD/CAM system ...

متن کامل

fracture strength of three-unit implant supported fixed partial dentures with excessive crown height fabricated from different materials

objectives: fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (chs). the purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (fpds) with excessive crown height, fabricated from three different materials. mater...

متن کامل

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

PURPOSE The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design...

متن کامل

مقایسه گپ مارژینال فریم ورک‌های زیرکونیایی متکی بر ایمپلنت دو سیستم CAD/CAM

Background and Aims: Marginal accuracy is a crucial factor influencing the clinical long-term reliability of implant-supported fixed dental prostheses (FDPs). The aim of this in vitro study was to evaluate the marginal fit of three-unit zirconia bridge frameworks fabricated using two different computer-aided design (CAD)/ computer-aided manufacturing (CAM) systems (AmannGirrbach and Zirkonzahn...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 32  شماره 1

صفحات  22- 28

تاریخ انتشار 2019-07

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023