Development of a Phase Space Generator software for Medical Linear Accelerator Applications

نویسندگان

  • Mahdi Ghorbani Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Velenjak, Tehran, Iran
  • Marziyeh Behmadi Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Mohammad Mohammadi Royal Adelaide Hospital, Department of Medical Physics, Adelaide, Australia. Reza Radiotherapy and Oncology Centre (RROC), Devision of Medical Physics, Mashhad, Iran
چکیده مقاله:

Introduction: During the last decades, simulation of radiation therapy treatment conditions in treatment room for studying with more details in comparison with treatment planning system (TPS) is taken into consideration. The most problem with starting these kind of researches is the geometry of Medical linacs and verification of the accelerators. Therefore, researchers tried to produced phase space after constant parameters of linacs (target, primary collimator, flattening filters) before jaws and offering them to the other researchers specially by International atomic energy agency in IAEA or ROOT format. The goal of this study is to write a phase space generator software which can produced phase space for multiple medical linear accelerators in ROOT and IAEA format. These phase space can have been used in Geant4, Gate, EGSnrc and PENELPOE as a source.   Materials and Methods: In the first step, the head of multiple medical linac accelerators like Varian (Novalis TX, Trilogy, Clinac iX, Clinac DX, Clinac 2100 C/D, Clinac 21 EX, Clinac CX, Truebeam), Simens (Primus, Primus pulse, Artiste and ONCOR) and Elekta (Synergy, Compact, SL) in photon and electron mode in the present of wedge and different applicators were simulated and verified with Geant4. For verification of the simulated linac’s heads, the percentage depth doses (PDDs) and Profiles were compared with experimental data. The comparisons were done with Gamma Index code (3%, 3mm) in MATLAB. In the second step, a software was written which can produce phase space in two formats for the simulated heads without accessing the users to the heads geometry. To validate the accuracy and precision of written software results (Phase space files, PDDs and Profiles), the data which were extracted from these software was evaluated with the Geant4 results.   Results: Based on the Gamma Index results in the first step and evaluation of the produce Phase Space files, the software’s results have a good agreement with Geant4 and Experimental data.   Conclusion: In the written software several medical linacs were modeled and the users can produce ROOT and IAEA phase space format after adjust (regulate) the jaws or MLCs in needed positions and use them in different Monte Carlo codes. In this code most of the Varian, Siemens and Elekta models were implemented and the users can select the present of wedge and change its angel and even positioned the different form of shield in the beam line. Furthermore, user can define new accelerator using simple input Like EGS Code. These parameters are the advantages of this software related to the similar softwares like PRIMO.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of a medical linear accelerator for teaching purposes

Simulation software for medical linear accelerators that can be used in a teaching environment was developed. The components of linear accelerators were modeled to first order accuracy using analytical expressions taken from the literature. The expressions used constants that were empirically set such that realistic response could be expected. These expressions were programmed in a MATLAB envir...

متن کامل

LACore: A Large-Format Vector Accelerator for Linear Algebra Applications

....................................................................................................................................................... iii Table of

متن کامل

Software Development for Simulation of Reformer Furnace

In recent years, lots of research has been done on effective usage of natural gas; the first step in these processes is conversion of natural gas to Syngas. Natural gas reforming process by refomer furnace is commonly used for syngas and hydrogen production. In this paper, a windows based software, RIPI-RefSim, is introduced. By using proper heat, mass, kinetic and thermodynamic models as w...

متن کامل

Advances in Medical Linear Accelerator Technology

Technological inventions and developments have created new possibilities and breakthroughs in medical era. The classic example is the discovery of X-rays by W.C. Roentgen, one hundred years ago. The first dawning rays appeared quite literally just before the beginning of the 20th century. In 1895 a German physicist named Wilhelm Conrad Roentgen accidentally discovered a form of radiation that c...

متن کامل

PHEGAS: a phase-space generator for automatic cross-section computation

A phase-space generation algorithm, capable to efficiently integrate the squared amplitude of any scattering process, is presented. The algorithm has been implemented in a Monte Carlo program, PHEGAS, which, using HELAC, a helicity amplitude computational package, can be used for automatic cross-section computation and event generation. Results for several scattering processes with four, five a...

متن کامل

A hierarchical phase space generator for QCD antenna structures

We present a “hierarchical” strategy for phase space generation in order to efficiently map the antenna momentum structures, typically occurring in QCD amplitudes.

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  11- 11

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023