Determination of stationary region boundary in multiple reference frames method in a mixing system agitated by Helical Ribbon Impeller using CFD

نویسندگان

  • Faramarz Hormozi School of Chemical& Petroleum and Gas Engineering, Semnan University, Semnan, Iran.
  • Mansour Jahangiri School of Chemical& Petroleum and Gas Engineering, Semnan University, Semnan, Iran.
  • Maryam Sanaie-Moghadam School of Chemical& Petroleum and Gas Engineering, Semnan University, Semnan, Iran.
چکیده مقاله:

The multiple reference frames (MRF) method is the most suitable method tosimulate impeller rotation in mixing systems. Precise determination of stationaryand moving zones in MRF method leads to accurate results in mixing performance.In this research, the entire volume of mixing system was divided into two zones.The kinetic energy values were used to distinguish the zones with differentvelocities. The low-velocity zones, close to zero, were considered as the stationaryzone and higher velocities were considered as the moving zone. The standardgeometrical parameters were used for mixing system. The axial velocity and axialflow number were compared with literatures for validation. The values fordimensionless diameter of stationary zone at different Reynolds numbers wereachieved for Newtonian and non-Newtonian fluids that are in agreement withvalues applied in literatures. The results show that the dimensionless diameter ofstationary zone decreases as Reynolds number increases.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

determination of stationary region boundary in multiple reference frames method in a mixing system agitated by helical ribbon impeller using cfd

the multiple reference frames (mrf) method is the most suitable method tosimulate impeller rotation in mixing systems. precise determination of stationaryand moving zones in mrf method leads to accurate results in mixing performance.in this research, the entire volume of mixing system was divided into two zones.the kinetic energy values were used to distinguish the zones with differentvelocitie...

متن کامل

Modeling of Oxygen Transfer Correlations for Stirred Tank Bioreactor Agitated with Atypical Helical Ribbon Impeller

Problem Statement: Mixing filamentous fungi entails delicate balance between promoting high volumetric oxygen transfer coefficient (kLa) while keeping low hydrodynamic stresses in the microenvironment of cultures. This study examined the oxygen transfer capability of a prototype low shear helical impeller as a potential replacement for the standard Rushton turbine. Approach: The dependence of k...

متن کامل

Flow and Mixing Performance in Helical Ribbon Mixers

This paper explores the effect of impeller design on the chaotic mixing in a helical ribbon mixer. Numerical simulations using the Smoothed Particle Hydrodynamics (SPH) method are used to solve for the fluid flow around the moving impellor. The mixing flow is visualised by extracting the hyperbolic Lagrangian Coherent Structures (LCS) of the flow from the Finite-Time Lyapunov Exponent (FTLE) fi...

متن کامل

multiwavelength pectrophotometric determination of stability constants of 4-(2– thiazolylazo) resorcinol (tar) with la3+, y3+ and th4+ in organic-water mixed solvents by chemometrics method & simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares calibration method

تشکیل کمپلکس های tarبا یون های لانتانیم, ایتریم و توریم در دمای 25 درجه، قدرت یونی ثابت 0.1 مولار و در ph ثابت در مخلوط حلال های اتانول – آب و استونیتریل – آب با استفاده از روش های اسپکتروفوتومتری مورد بحث و بررسی قرار گرفت. داده های اسپکتروفوتومتری با استفاده از نرم افزار squad پردازش شدند تا ثابت های تشکیل کمپلکس اندیکاتور – فلز را محاسبه کند. نتایج نشان می دهد که درصد حلال آلی در مخلوط حلال ...

15 صفحه اول

Mixing of the Immiscible Liquids in the Entrance Region of a T-Type Chamber Using Laser Induced Fluorescence (LIF) Method

A Laser Induced Fluorescence technique (LIF) has been used to study the mixing behavior of two emerging streams in a T-Type mixing chamber. A mixing index on the basis of digital image light intensities is calculated. It has been shown that averaging over more than 800 images leads to a stable mixing index calculation. Moreover, the effect of equal and un-equal flow rates on the mixing behavior...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 1

صفحات  31- 37

تاریخ انتشار 2015-04-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023