Design and Experimentation of Roll Bond Evaporator for Room Air Conditioner with R-22 as Refrigerant
نویسندگان
چکیده مقاله:
The world is looking towards producing products which consume less power without compromising on quality of life. The increase in use of refrigeration and air conditioning appliances are contributing to global warming. The world wide temperatures are shooting up at an increasing rate. This paper presents a design of roll bond evaporator as the heat exchanger to provide cooling in room air conditioner. Presently all room air conditioners use tube and fin evaporators. This study presents roll bond evaporator as a power saving alternative to tube and fin evaporator. The experimentation has been done and comparative study of roll bond evaporator with that of tube and fin evaporator is presented. It was found out that while the tube and fin evaporator took 30 minutes to get a uniform temperature of 25 ºC in the room, the roll bond evaporator took only 25 minutes to get that uniform temperature, thereby saving 5 minutes of running of air conditioner.
منابع مشابه
Seasonal Applicability of Refrigerant Release Technology in Room Air Conditioner
The refrigerant release technology relieves even eliminates the over-compression loss of scroll compressor by bypassing the refrigerant in the compression chamber to the suction pipe under small system pressure ratio conditions. Because the room air conditioner works in mild conditions at most of the time, its seasonal energy performance is expected to be effectively improved by the refrigerant...
متن کاملEvaluation of a Refrigerant R410A as Substitute for R22 in Window Air-conditioner
CFCs have been phased out, except for essential users, and HCFCs are to be eliminated by 2020, because of their ozone depletion potential. This generates a need for the investigation of zero ozone depletion potential (ODP) refrigerants or refrigerant blends. R410A is among newer brand of refrigerant blends, with zero ODP. The biggest difference to R22 is the pressure levels generated which are ...
متن کاملApplication of Nonazeotropic Refrigerant Mixtures in Multi-Zone Heat Pump Room Air Conditioner with Hot Water System
متن کامل
Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance
An experimental investigation was implemented to determine the capacity degradation due to non-uniform refrigerant and air flow distributions, and to assess the potential to recover the lost capacity via controlling refrigerant distribution between individual refrigerant circuits. The tests were performed on a three-circuit, threedepth-row, finned-tube evaporator. Refrigerant inlet quality, exi...
متن کاملWindow Air Conditioner with Orthodox Refrigerants
The system design of window air conditioner does not evolve in one day. Due to the continous efforts are taken by the refrigeration and air conditionging professionals, successful and economic models of window air conditioners are currently used. This paper states about the development of window air conditioner with phase change material and water as refrigerants. Developed air conditioner was ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 30 شماره 4
صفحات 558- 566
تاریخ انتشار 2017-04-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023