Cryotherapy is more effective and faster than Q-switched Nd-YAG laser fordepigmentation in universal vitiligo patients

نویسندگان

  • Ramin Radmanesh
چکیده مقاله:

Background: Although cryotherapy has been reported as atechnique for depigmenting residual pigmented patches inpatients with universal vitiligo, Q-switched Nd-YAG lasershave not yet been used for this purpose. The aim of this studywas to compare the efficacy of cryotherapy with that of 532nmQ-switched Nd-YAG laser therapy for depigmentation in patientswith universal vitiligo.Method: Six adult patients (4 male and 2 female) with universalvitiligo and facial residual pigmented patches were treatedsimultaneously with cryotherapy on the right and the frequencydoubled532nm Q-switched Nd-YAG laser therapy on the leftside. The laser parameters used were spot size 3-5mm, frequencyrate 10 hertz, and the fluence was 5J/cm2. The cryo system wasa closed contact CO2 Cryo gun. The patients were scheduled tobe treated monthly.Result: The depigmentation was complete after three successivesessions of cryotherapy and 30-45 days after the last session, incomparison with simultaneous 30-70% depigmentation of the laserside. No scar or permanent sequellae developed on either side.Conclusion: Cryotherapy is more effective and fast-actingthan Q-switched Nd-YAG laser for depigmentation of residualpigmented patches in patients with universal vitiligo.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repigmentation of vitiliginous facial area after Q-switched Nd-YAG laser therapy for depigmentation: Is it a case of true reverse Koebner phenomenon in vitiligo?

The patients with universal vitiligo and residual pigmented patches usually do not benefit from available repigmenting methods and are better scheduled for depigmentation by medical, laser,and or freezing procedures. A 37-year-old lady with universal vitiligo and remaining pigmentation in the left anterior chest wall, ...

متن کامل

بررسی و مقایسه اثر q-switched nd yag laser و erbium laser در درمان ضایعات پیگمانته

هدف: این مطالعه به منظور بررسی و مقایسه اثر q-switched nd yag laser و erbium laser در درمان ضایعات پیگمانته انجام شده است. روش مطالعه: 116 فرد مبتلا به ضایعات پیگمانته از نوع فرکل و خال وارد مطالعه شدند که 58 مورد با استفاده از q-switched nd yag laser و 58 مورد با لیزر erbium درمان شدند و در نهایت میزان اثربخشی (از بین رفتن کامل ضایعات) در دو گروه تعیین و مقایسه گردید. یافته ها: در این مطالعه...

15 صفحه اول

Q - switched Cryogenically Cooled Yb : YAG Laser

This work describes a cryogenic, electro-optically -switched Yb:YAG laser that generates 114-W average TEM power with 47% optical-to-optical efficiency. Pulse repetition frequency is 5 kHz, pulse duration is 16 ns full-width at half-maximum, and is less than 1.05.

متن کامل

Efficient Selection of High-Order Laguerre–Gaussian Modes in a Q-Switched Nd : YAG Laser

Intra-cavity binary phase elements are incorporated into a -switched Nd : YAG laser resonator to obtain efficient high-order transverse mode selection. The resonator configuration is analyzed using the propagation-matrix diagonalization method and the Fox–Li algorithm, and a simple model for predicting the relative output powers of the selected modes is developed. The predicted results are veri...

متن کامل

Tunable subpicosecond dye laser amplified at 1 kHz by a cavity - dumped , Q - switched , and mode - locked Nd : YAG laser

Tunable subpicosecond pulses are generated by synchronously pumping a dye laser with the pulse-compressed and frequency-doubled output of an acousto-optically mode-locked cw Nd:YAG laser. The pulses are amplified at a repetition rate of 1 kHz, using the frequency-doubled output of a cavity-dumped, acousto-optically mode-locked, Qswitched, cw pumped Nd:YAG laser. Amplified transform-limited puls...

متن کامل

100 - W Q - switched Cryogenically Cooled Yb : YAG Laser

This work describes a cryogenic, electro-optically -switched Yb:YAG laser that generates 114-W average TEM power with 47% optical-to-optical efficiency. Pulse repetition frequency is 5 kHz, pulse duration is 16 ns full-width at half-maximum, and is less than 1.05.

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 1

صفحات  17- 20

تاریخ انتشار 2013-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023