Construction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography

نویسندگان

  • Behzad Mohsenzadeh Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iran
  • Fereshte Rahmani Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iran
  • Leila azimi Departeman of imaging of Velayat hospital, University of medical science, Qazvin, Iran
  • Mohammad Reza Deevband Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iran TEL: 09123044609, E-mail: [email protected]
  • Zeinab Kaveh Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iran
چکیده مقاله:

Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be considered as a good alternative for the geometrical body equivalent Phantom. Materials and Methods: This geometrical body equivalent phantom has been employed in order to measure the absorbed dose using Monte Carlo calculation code. Using this phantom in Monte Carlo space in which x-ray tube system has been simulated as well makes it possible to analyze the weaknesses and x-ray discrepancies. The Phantom is made of Plexiglas. Results: Validity of the tests with lower than 5% error, deep dose in Monte Carlo and the experimental space as well collectively confirms the simulator program. After the process of simulation, the homogeneous phantoms chest equivalent in children were produced with different thicknesses for different age groups. Simulated as well makes it possible to analyze the weaknesses and x-ray discrepancies. Conclusion: The phantom designed in this study can be used to evaluate the dose of children in different age groups, Also, using image quality control tools such as contrast, resolution, etc. in this phantom can be used to evaluate the parameters of the image quality in the actual condition of the patient's body. In this study, An attempt was made to provide a new method for the construction of a chest equivalent phantom that would include all age groups.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a quality control phantom for digital chest radiography

RATIONALE AND OBJECTIVES To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects pla...

متن کامل

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  99- 99

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023