Comparison the performance of different reverse osmosis membrane modules by CFD modeling

نویسندگان

  • E. Kashi Sh. Ehsani Rad St., Enqelab St., Parsa Sq., Ahmadabad Mostoufi Rd., Azadegan Highway
  • Kh. Rostami Department of Biotechnology, Iranian Research Organization for Science and Technology (IROST), P.O. Box 33535111, Tehran, Iran
  • M. Bahoosh Department of Chemical Technologies, Iranian Research Organization for Science and Technology (IROST), P.O. Box 33535111, Tehran, Iran
  • S. Shokrollahzadeh Department of Chemical Technologies, Iranian Research Organization for Science and Technology (IROST), P.O. Box 33535111, Tehran, Iran
چکیده مقاله:

Reverse osmosis is a commonly used process in water desalination. Due to the scarcity of freshwater resources and wastewater problems, a lot of theory and experimental studies have been conducted to optimize this process. In the present study, the performance of reverse osmosis membrane module of salt–water separation was simulated based on computational fluid dynamics technique and solution-diffusion theory. Eight geometries of membrane modules four flat sheets, and four tubular membranes were investigated. It was found that if the membrane surface area and inlet flow rate were kept constant for the eight modules, the pressure drop and permeated flow rate would be approximately similar for some geometries (such as the performance of primary flat sheet channel is same as 3 tubular membranes with R=1/3 Rref). The results also showed that because of the phenomenon of concentration polarization, if it is possible to use more membranes with a smaller length, it can reduce the pressure drop and increase the permeation flux of water. Furthermore, the results showed that in similar conditions between the tubular and the plate membranes; the tubular one is more suitable for the water permeation due to its ease of construction and its ability to withstand ECP.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Organoclay on the Performance of Reverse Osmosis Membrane

This study investigated the effect of Cloisite15A (C15A) organoclay in the substrate layer on the performance of reverse osmosis (RO) membranes. The substrate of the RO membranes was modified using different loading of C15A (ranging from 0.3 - 0.7 wt%) within polysulfone (PSf) substrate and the polyamide (PA) selective layer was formed on the top. Effect of the modified substrate layer on the w...

متن کامل

The Effect of Osmotic Dehydration on Reverse Osmosis Membrane Performance

Akin type (asymmetric) reverse osmosis membranes undergo an irreversible osmotic dehydration upon coming into contact (skin side) with salt solutions. The extent of consequent changes (in appearance; decrease in linear dimension, water flux and salt rejection) are dependent on the salt concentration. These observations are correlated with the expected morphological changes taking place duri...

متن کامل

the effect of osmotic dehydration on reverse osmosis membrane performance

akin type (asymmetric) reverse osmosis membranes undergo an irreversible osmotic dehydration upon coming into contact (skin side) with salt solutions. the extent of consequent changes (in appearance; decrease in linear dimension, water flux and salt rejection) are dependent on the salt concentration. these observations are correlated with the expected morphological changes taking place during d...

متن کامل

Economic comparison of transverse and longitudinal flow hollow fiber membrane modules for reverse osmosis and ultrafiltration

The presently used hollow fiber membrane modules consist of a bundle of fibers in a cylindrical polymer or metal shell parallel to the shell axis. The feed solution flows either through the lumen or at the outside parallel to the fibers. This paper compares the performance of these modules with a new transverse flow module where the hollow fibers are positioned perpendicularly to the flow direc...

متن کامل

A numerical study of the effect of channel spacers on the performance of cross-flow forward osmosis membrane modules

In this paper, we perform two-dimensional simulations of cross-flow forward osmosis (FO) membrane modules in the presence of draw and feed channel spacers. For this purpose, the equations corresponding to the conservation of mass, momentum, and convection-diffusion for the mass fraction of solute are solved using a commercial finite volume flow solver. We consider six configurations of channel ...

متن کامل

The Pursuits of Ultimate Membrane Technology including Low Pressure Seawater Reverse Osmosis Membrane developed by “Mega-ton Water System” Project

Reverse osmosis (RO) technology has been widely applied to water treatment such as seawater desalination, and large RO plants are many in operation around the world. Moreover, much larger plants will be required to secure sufcient water resource in the near future because global water shortage and quality problems are still getting more serious. Mega-ton Water System pr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 1

صفحات  101- 116

تاریخ انتشار 2019-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023