Comparison of the myocardial perfusion and wall motion results by ECG-Gated 99mTc-MIBI SPECT, before and after CABG for evaluation of myocardial viability [Persian]
نویسندگان
چکیده مقاله:
It is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. Having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ECG-Gated is an appropriate method for this purpose. The aim of this study was to compare the results of myocardial perfusion and wall motion before and after Coronary Artery Bypass Grafting (CABG), as well as assessment of the efficiency of these parameters for detection of myocardial viability. Forty patients with positive history of previous myocardial infarction and candidate for CABG underwent ECG-Gated SPECT scanning 1 month before and 2-3 months after surgery. Findings of myocardial perfusion and wall motion, obtained from the two phases of the study, were compared. The results showed that functional status of some preoperatively severely hypoperfused segments, recovered significantly after CABG, which proved existence of viable tissue in these regions. Also, septal wall motion presented no statistically significant changes after CABG. These results suggest that septal perfusion and motion are not reliable parameters for the assessment of surgical outcome in this region. Most of the myocardial walls demonstrated considerable wall motion improvement after operation. Concerning the results of this research, as a marker of viable against nonviable myocardial tissue, we recommend revision of applying the severity of perfusion defect, alone, as well as taking the wall motion parameter into consideration, to improve diagnostic accuracy of the SPECT method.
منابع مشابه
comparison of the myocardial perfusion and wall motion results by ecg-gated 99mtc-mibi spect, before and after cabg for evaluation of myocardial viability [persian]
it is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ecg-gated is an appropriate method for this purpose. the aim of this study was to compare the results of myocardial perfusion a...
متن کاملEvaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy
Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...
متن کاملThe value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]
Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کاملevaluation of myocardial perfusion and function after kidney transplantation by gated spect myocardial perfusion scintigraphy
introduction: the aim of this study was to evaluate the effect of successful kidney transplantation (kt) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-spect) in patients suffering from end-stage renal disease. ...
متن کاملClinical usefulness of ECG-gated 18F-FDG PET combined with 99mTC-MIBI gated SPECT for evaluating myocardial viability and function.
OBJECTIVES This study sought to evaluate an imaging approach using gated 99mTc-MIBI (MIBI) SPECT and gated 18F-FDG (FDG) PET for assessment of myocardial viability and cardiac function. METHODS Forty-eight patients (38 men, mean age 68.1 +/- 9.6 years) underwent ECG-gated FDG PET and MIBI SPECT within a week. The baseline diagnoses were coronary artery disease (31), mitral regurgitation (1), ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 11 شماره 1
صفحات 29- 32
تاریخ انتشار 2003-11-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023