Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

نویسندگان

  • Ejlali, Masoud
  • Esfahanizade, Gholam reza
چکیده مقاله:

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Islamic Azad University. ***- Professor and Chief of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. Background and Aim: When a complete denture is replaced with an overdenture supported by implant, masticatory efficiency will be improved. There are a lot of controversies on the use of the best attachments in overdentures. The aim of this study was to compare the stresses transferred to the implant supported overdentures in mandible with bar, ball and zaag attachments using photoelastic technique. Materials and Methods: In this descriptive in – vitro study, stresses transferred to the implants supported overdentures with bar, ball and zaag attachments were analyzed using photoelastic method. Two implants were installed in the canine area 8 mm from the midline. Vertical and oblique loads of 30Ib were applied to the first molar unilaterally. Resultant stress distribution with ball, bar and zaag attachments were evaluated. Results: The bar attachments exhibited the most stress transferred to the implants on the loaded side and opposite side. When the model was subjected to the posterior vertical load. The oblique load transferred to the implants was more than the vertical load. The ball and zaag attachments transferred the vertical load to both implants and edentulous area. These both attachment systems exhibited more stress on implants in oblique load where as the edentulous ridge was stress free. Conclusion: Bar attachments transferred more stress to the implant bodies than ball and zaag attachments in both oblique and vertical loads and zaag attachments transferred more stress to the implant as compared with the ball ones. Key words: Implant - Overdentures - Attachment - Ball - Bar - Zaag – Photoelasticity

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications associated with the ball, bar and Locator attachments for implant-supported overdentures.

BACKGROUND The purpose of this clinical study was to evaluate the complications associated with the different attachments used in implant-supported overdentures, including prosthetic problems and implant failures. A comparison of ball, bar and Locator (Zest Anchors, Inc, homepage, Escondido, CA, USA) attachments, in completely edentulous patients with two, three or four implants, was conducted....

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

comparison of three attachments in implant-tissue supported overdentures: an in vitro study

objective: retention and resistance of the implant-tissue supported overdenture may be affected by the type of attachment. the aim of this research was to compare the retention and resistance of nobel biocare ball (nbb), nobel biocare bar and clip (nbbc) and sterngold era red (erar) attachments on an implant-tissue supported overdenture model. materials and methods: the attachment samples were ...

متن کامل

Comparison of Three Attachments in Implant-Tissue Supported Overdentures: An In Vitro Study

OBJECTIVE Retention and resistance of the implant-tissue supported overdenture may be affected by the type of attachment. The aim of this research was to compare the retention and resistance of Nobel Biocare Ball (NBB), Nobel Biocare Bar and Clip (NBBC) and Sterngold ERA Red (ERAR) attachments on an implant-tissue supported overdenture model. MATERIALS AND METHODS The attachment samples were ...

متن کامل

a comparison of teachers and supervisors, with respect to teacher efficacy and reflection

supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 17  شماره 4

صفحات  66- 75

تاریخ انتشار 2005-07

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023