Comparison of Soft Tissue Thermal Changes Induced by Three Types of Diode Lasers at 810, 940, and 980nm Wavelengths

نویسندگان

  • A Azizi Professor,Oral Medicine Dept, faculty of Dentistry,Tehran medical sciences , Islamic Azad University , Tehran, Iran.
  • AR Mirzaei Educational trainer at international Academy of RWTH Aachen university
  • N Gutknecht Professor of of RWTH Aachen university, Department of operative Dentistry, Periodontology and Preventive Dentistry
  • N Moezzi ghadim Assistant professor, Oral Medicine Dept, faculty of Dentistry,Tehran medical sciences
  • S Chaychi salmas Dentist
  • S Shahbazi Dentist
  • SH lawaf Associate professor, Prosthodontics Dept, Faculty of Dentistry, Tehran medical sciences
چکیده مقاله:

Background and Aim: Diode laser is a great choice for soft tissue surgery. The diode laser is partially absorbed by hard dental tissues, making it safe for soft tissue surgery. This study aimed to compare the tissue thermal changes induced by three types of diode lasers at 810, 940, and 980nm wavelengths. Materials and Methods: In this in-vitro experimental study, using a diode laser device (continuous mode with a 400μm fiber tip) at each of the 810, 940, and 980nm wavelengths and powers of 1, 2, and 3W in contact mode, incisions with the length of 2cm were made on pieces of meat over a period of 10 seconds. The primary and secondary temperatures were measured using a thermocouple. Data were analyzed using two-way analysis of variance (ANOVA). Results: Tissue temperature changes induced by diode laser at 810nm/3W were significantly greater than that of 2W power. These changes were higher with 2W of power compared to 1W (P<0.05). Temperature changes induced by diode laser at 940nm/2 and 3W were significantly greater than that of 1W power (P<0.05). Temperature changes induced by diode laser at 980nm/3W were significantly greater than that of 2W power. Tissue temperature changes were higher with 2W of power compared to 1W (P<0.05). Conclusion: Diode laser (continuous mode with a 400µm fiber tip) at 3W of power and 980nm wavelength caused the highest rate of thermal changes. The 810nm diode laser with the power of 1W caused the slightest heat changes in the soft tissue.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Effect of 810 nm and 940 nm Diode Lasers on Solobacterium Moorei in Vitro

Background and aim: Given the role of Solobacterium moorei in bacteremia, septicemia, oral infections, halitosis, and periodontal diseases and previous research defects considering the important role of laser in comparison with the application of antimicrobial agents, the purpose of this research was to compare the effect of 810nm and 940nm lasers on Solobacterium moorei in vitro situation. Mat...

متن کامل

The thermal effects of therapeutic lasers with 810 and 904 nm wavelengths on human skin.

OBJECTIVE To investigate the effect of therapeutic infrared class 3B laser irradiation on skin temperature in healthy participants of differing skin color, age, and gender. BACKGROUND Little is known about the potential thermal effects of Low Level Laser Therapy (LLLT) irradiation on human skin. METHODS Skin temperature was measured in 40 healthy volunteers with a thermographic camera at la...

متن کامل

Diode laser application in soft tissue oral surgery.

INTRODUCTION Diode laser with wavelengths ranging from 810 to 980 nm in a continuous or pulsed mode was used as a possible instrument for soft tissue surgery in the oral cavity. DISCUSSION Diode laser is one of laser systems in which photons are produced by electric current with wavelengths of 810, 940 and 980nm. The application of diode laser in soft tissue oral surgery has been evaluated fr...

متن کامل

‏‎suppression of coke formation in thermal cracking by coke inhibitors‎‏

‏‎the main purpose of this research was to:1.develop a coking model for thermal cracking of naphtha.2.study coke inhibition methods using different coke inhibitors.developing a coking model in naphtha cracking reactors requires a suitable model of the thermal cracking reactor based on a reliable kinetic model.to obtain reliable results all these models shall be solved simultaneously.for this pu...

15 صفحه اول

diode laser application in soft tissue oral surgery

introduction: diode laser with wavelengths ranging from 810 to 980 nm in a continuous or pulsed mode was used as a possible instrument for soft tissue surgery in the oral cavity. discussion: diode laser is one of laser systems in which photons are produced by electric current with wavelengths of 810, 940 and 980nm. the application of diode laser in soft tissue oral surgery has been evaluated fr...

متن کامل

Histologic evaluation of thermal damage produced on soft tissues by CO2, Er,Cr:YSGG and diode lasers.

OBJECTIVE The aim of this in vitro experimental study was to perform histological evaluation of the thermal effect produced on soft tissue irradiated with CO2, Er,Cr:YSGG or diode lasers. STUDY DESIGN Porcine oral mucosa samples were irradiated with Er,Cr:YSGG laser at 1 W with and without water / air spray, at 2 W with and without water / air spray, and at 4 W with water / air spray, with CO...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره None

صفحات  6- 12

تاریخ انتشار 2020-05

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023