Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
نویسنده
چکیده مقاله:
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT protocols (i.e., A: 120 KV /150 mA, FBP; B: 120KV/ (20-150) mAs, IDREAM) to scan water and acrylic phantoms. A number of 40 patients were assigned to two CT protocols (C: n=20, 120KV/160 ±10 mAs, FBP and D: n=20, 120 KV/ (30-150 mAs, IDREAM), the two groups (C and D) were then referred to abdomen and pelvis CT scan (Sinovision, insitum 16) with contrast. Image quality parameters, dose calculations were measured for all groups (i.e., A, B, C, and D). Results: Group B had a highly significant SNR with less significant noise (P<0.05), in comparison with group A. In addition, uniformity was markedly higher for group B (P<0.05) in water phantom and insignificantly different (P>0.05) in acrylic phantom, as compared to group A. CTDIvol (A: 13.94 mGy ; B: 6.91 mGy , P<0.05 ) and DLP (A:501.76 mGy.cm ; B :248.88 mGy.cm). Noise and SNR were significantly different (P<0.05) in group D against C. CTDIvol (C: 30.3±5.2 mGy ; D : 15.4 ±2.7 mGy, P<0.05 ) , DLP (C:544±100 mGy.cm; D :272.3±50.3 mGy.cm ,P<0.05) and the effective dose (C:8.1±1.5 mSv; D :4.08±0.75 mSv,P<0.05) Conclusion: The results of the present study were indicative of the feasibility of IDREAMas an iterative reconstruction algorithm.
منابع مشابه
Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملHow Different Iterative and Filtered Back Projection Kernels Affect Computed Tomography Numbers and Low Contrast Detectability.
OBJECTIVE The aim of this study was to evaluate how different iterative and filtered back projection kernels affect the computed tomography (CT) numbers and low contrast detectability. METHODS Five different scans were performed at 6 different tube potentials on the same Catphan 600 phantom using approximately the same dose level and otherwise identical settings. The scans were reconstructed ...
متن کاملComparison of image quality from filtered back projection, statistical iterative reconstruction, and model-based iterative reconstruction algorithms in abdominal computed tomography: Erratum
The purpose of this study was to compare the image noise-reducing abilities of iterative model reconstruction (IMR) with those of traditional filtered back projection (FBP) and statistical iterative reconstruction (IR) in abdominal computed tomography (CT) imagesThis institutional review board-approved retrospective study enrolled 103 patients; informed consent was waived. Urinary bladder (n = ...
متن کاملFiltered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study.
PURPOSE To compare objective and subjective image quality parameters of three image reconstruction algorithms of different generations at routine multidetector computed tomographic (CT) examinations of the abdomen. MATERIALS AND METHODS This institutional review board-approved study included 22 consecutive patients (mean age, 56.1 years ± 15.8 [standard deviation]; mean weight, 79.1 kg ± 14.8...
متن کاملUniversal back-projection algorithm for photoacoustic computed tomography.
We report results of a reconstruction algorithm for three-dimensional photoacoustic computed tomography. A universal back-projection formula is presented for three types of imaging geometries: planar, spherical, and cylindrical surfaces. A solid-angle weighting factor is introduced in the back-projection formula to compensate for the variations of detection views. A method for implementing this...
متن کاملComputed Tomography Iterative Reconstruction Techniques.
For all their diagnostic value, computed tomography (CT) examinations have relatively high radiation exposure. Past efforts to decrease patient dose emphasized advances in data acquisition technology because attempts to decrease dose resulted in increased image noise from filtered back projection reconstruction techniques. Iterative reconstruction techniques lead to reduced dose and maintain im...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 17 شماره 3
صفحات 170- 174
تاریخ انتشار 2020-05-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023