Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran
نویسنده
چکیده مقاله:
This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of 2056kW.h.m-2, a total of 3577kW.h.y-1 and 4201kW.h.y-1 of heat energy were collected by 4m2 FPC and, ETC systems, respectively. The annual average energy efficiency by the FPC system was 43%, while its annual solar fraction was 50%. The ETC system had 51% energy efficiency with 58% solar fraction. The economic analysis showed that both solar water heating systems are not economically viable under prevailing costs in Iran. Furthermore, according to the obtained results, the FPCs are more favorable than the ETCs due to its economic analysis and energy performance. These results provide useful information for households and policymakers.
منابع مشابه
Design Considerations for Residential Solar Heating and Cooling Systems Utilizing Evacuated Tube Solar Collectors
As solar heating systems become a commercial reality, greater efforts are now being employed to incorporate solar cooling components in order to obtain a complete solar heating and cooling system, and thus take advantage of the cost-effectiveness of year-round use of the solar equipment. The solar heating and cooling system design presented in this paper incorporates design considerations which...
متن کاملExperimental investigation on performance comparison of nanofluid-based direct absorption and flat plate solar collectors
In the present work, a prototype of a new type of solar collectors, which called Direct Absorption Solar Collector, was built and its thermal performance is experimentally compared with conventional flat plate solar collector under transient and steady state conditions. Different volume fractions of multi wall carbon nanotubes in water and ethylene glycol mixture (70%:30% in volume) were used a...
متن کاملInvestigating the effect of hot water consumption profile on the performance of solar water heating systems
In this paper, a forced circulation solar water heater system is simulated for different hot water consumption profiles using flat plate collectors as well as evacuated tube collectors. The profiles studied are the actual samples of hot water consumption profiles for different commercial centers and institutions. Dynamic simulation outputs of system thermal performance are used as economic anal...
متن کاملExperimental investigation on performance comparison of nanofluid-based direct absorption and flat plate solar collectors
In the present work, a prototype of a new type of solar collectors, which called Direct Absorption Solar Collector, was built and its thermal performance is experimentally compared with conventional flat plate solar collector under transient and steady state conditions. Different volume fractions of multi wall carbon nanotubes in water and ethylene glycol mixture (70%:30% in volume) were used a...
متن کاملExergy Analysis of Flat Plate Solar Collectors
This study proposes the concept of the local heat loss coefficient and examines the calculation method for the average heat loss coefficient and the average absorber plate temperature. It also presents an exergy analysis model of flat plate collectors, considering non-uniformity in temperature distribution along the absorber plate. The computation results agree well with experimental data. The ...
متن کاملPerformance Study of a Solar Integrated Central Heating System of a Residential Building Using Trnsys- an Hourly Simulation Model (RESEARCH NOTE)
In this investigation, the performance of an existing heating system of a residential building incorporated with an array of solar thermal collectors was studied. For this purpose, transient systems simulation program model was assembled to estimate the hour-by-hour performance of the existing and the system equipped with the solar thermal collectors in terms of the provided space air condition...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 8 شماره 2
صفحات 143- 152
تاریخ انتشار 2020-06-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023