CNTs-COOH Paste Electrode for Detection of Temozolomide

نویسندگان

  • Chem Shenfeng Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
  • Gade Archana Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
  • Liu Haiqian Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
  • Liumin He Department of Biomedical Engineering, College of Life Science and Technology, Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
  • Rong Zhao Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
  • Sathish Reddy Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
  • Seeram Ramakrishana Center for Nanofibers and Nanotechnology, Department of Mechanical Engineering, Faculty of Engineering, National University of Singapore, Singapore, 117576, P.R. CHINA|Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
  • Xiao Qiao Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou, Guangdong, 510632, P.R. CHINA
چکیده مقاله:

The MWCNTs-COOH Paste Electrode (MCPE) was successfully used to study the electrochemical behavior of temozolomide in 0.2 M H2SO4 solution, phosphate buffer solution (0.1M PBS, pH 7.4) and 0.1M NaOH solution by Cyclic Voltammetry (CV) technique. The results exhibit that MCPE can remarkably enhance sensing and electrocatalytic activity towards the oxidation and reduction of temozolomide in acidic, neutral, and basic solutions. The effect of the scan rate exhibits the adsorption controlling process. The effect of pH range from 2 to 6 was investigated by cyclic voltammetry technique, from cyclic voltammetry study exhibits the peak current was pH-dependent with a slope of 68 mV/pH.  The detection limit (LOD)) at MCPE were found to be 0.056 mM,0.069 mM and 0.065 mM in 0.1M H2SO4, 0.1M PBS (pH 7.4)  and 0.1M NaOH solutions  respectively by Cyclic Voltammetric (CV) technique. Similarly, from Linear Scan Voltammetric (LSV) technique, the detection limits (LOD) were found to be 0.050 mM, 0.021mM and 0.036 mM in acidic, neutral, and basic solution respectively. The proposed method was successfully applied for the determination of temozolomide in the clinical sample.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Carbon Paste Electrode/EDTA/Polymer Sensor for Heavy Metals Detection

The method used to immobilize the polymer on the Disodium ethylenediamine tetraacetate (EDTA) modified carbon paste electrode (CPE/EDTA) has proved its effectiveness for the detection and chelation of heavy metals in aqueous solution. Its complex formation with Pb(II) was examined by square wave voltammetry and cyclic voltammetry. CPE/EDTA electrodes are predisposed to the phenomenon of dissolu...

متن کامل

Nanoporous Ag-CNTs foamed electrode for lithium intercalation

Intercalation of lithium into Ag-CNTs sample is reported here. We have used a nano-porous silver foam as a frame for deposition of the CNTs   inside   the   pores   by   electrophoresis   deposition   (EPD) technique. By using  chronopotentiometry method,  we  have noticed that the Li storage capacity of the prepared Ag-CNTs electrode was improved  noticeably  in  comparison  with  literature. ...

متن کامل

Epigallocatechin Gallate-Modified Graphite Paste Electrode for Simultaneous Detection of Redox-Active Biomolecules

In this study, simultaneous electrochemical detection of ascorbic acid (AA), dopamine (DA), and uric acid (UA) was performed using a modified graphite paste electrode (MGPE) with epigallocatechin gallate (EGCG) and green tea (GT) powder. It was shown that the anodic peak current increased in comparison with that of the graphite paste electrode (GPE) in the cyclic voltammograms. The optimal pH f...

متن کامل

Osmium-Polymer Modified Carbon Nanotube Paste Electrode for Detection of Sucrose and Fructose

The aim of the work was the modification of a carbon nanotube paste electrode with a highly original osmium-polymer hydrogel for the development of a new amperometric biosensor for detection of sucrose and fructose. The biosensor for sucrose is based on the activity of the enzymes invertase and fructose dehydrogenase (FDH) immobilized into a carbon nanotube paste (CNTP) electrode properly modif...

متن کامل

islanding detection methods for microgrids

امروزه استفاده از منابع انرژی پراکنده کاربرد وسیعی یافته است . اگر چه این منابع بسیاری از مشکلات شبکه را حل می کنند اما زیاد شدن آنها مسائل فراوانی برای سیستم قدرت به همراه دارد . استفاده از میکروشبکه راه حلی است که علاوه بر استفاده از مزایای منابع انرژی پراکنده برخی از مشکلات ایجاد شده توسط آنها را نیز منتفی می کند . همچنین میکروشبکه ها کیفیت برق و قابلیت اطمینان تامین انرژی مشترکان را افزایش ...

15 صفحه اول

nanoporous ag-cnts foamed electrode for lithium intercalation

intercalation of lithium into ag-cnts sample is reported here. we have used a nano-porous silver foam as a frame for deposition of the cnts   inside   the   pores   by   electrophoresis   deposition   (epd) technique. by using  chronopotentiometry method,  we  have noticed that the li storage capacity of the prepared ag-cnts electrode was improved  noticeably  in  comparison  with  literature. ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 39  شماره 1

صفحات  31- 41

تاریخ انتشار 2020-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023