Cement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration

نویسندگان

  • M. Haghpanahi
  • H. Ghomashchi
چکیده مقاله:

Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term implant failure and in this case the cement-implant interface cavities are very effective due to resultant stress concentration . In this study the theory of this problem, continuum and mathematical equations for an inhomogeneous material by using Eshelby’s equivalent inclusion method with a spherical void as a special type of inhomogenities is addressed and a new yield criterion with respect to the void’s volume fraction is derived and changes in material elasticity tensor concerning Mori-Tanaka’s theorem also determined, then by using finite element method and remeshing technique a macro scale cement-implant interface cavity is modeled and concerning the loss of strength due to void existence and the interface stress concentration, the crack initiation and propagation phenomenon is numerically investigated with respect to different orthopedic cement material properties. The results show that crack propagates at the interface at constant stress and strain by elastoplastic material and it propagates in cement bulk by considering elastic material properties for cement that both could cause implant loosening even in very small void’s volume fractions in which there are no significant changes in cement yield stress and elasticity tensor according to analytical solution. But numerical simulation shows that when a homogenous cement structure is achieved via high vacuum mixing method, there is a uniform stress distribution in the cement structure and no stress concentration zone forms even at high stress levels and also there is no appropriate local site for crack initiation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure of the cement-bone interface.

We report the early failure, at a mean of 37 months, of 17 femoral prostheses due to aseptic loosening at the cement-bone interface. In every case the prosthesis had been manufactured with a surface coating designed to enhance the strength of the cement-prosthesis interface. It is postulated that improving the bond at the cement-prosthesis interface may transfer increased stress to the cement-b...

متن کامل

Case series report: Early cement-implant interface fixation failure in total knee replacement.

BACKGROUND Early failure in cemented total knee replacement (TKR) due to aseptic loosening is uncommon. A small number of early failures requiring revision were observed at one hospital due to observed cement-implant fixation failure. The purpose of this case series is to report and identify possible causes for these early failures. METHODS Between May 2005 and December 2010, 3048 primary TKR...

متن کامل

Fracture Mechanics Analyses for Interface Crack Problems – a Review

Recent developments in fracture mechanics analyses of the interfacial crack problem are reviewed. The intent of the review is to renew the awareness of the oscillatory singularity at the crack tip of a bimaterial interface and the problems that occur when calculating mode mixity using numerical methods such as the finite element method in conjunction with the virtual crack closure technique. Es...

متن کامل

Using the Finite Element Analysis Method to Study the 3-point Bending Test for the Characterization of the Adherence

An elastic finite element analysis was conducted to evaluate the stress distribution in the initiation zone of the adhesive rupture during the 3-point bending test. This test is used to measure the adherence between a polyepoxy adhesive and aluminum alloy with different surface treatments. The purpose is to compare, in the high stress concentration areas, the stress fields calculated using fini...

متن کامل

Modular hip implant fracture at the stem-sleeve interface.

The use of modular implants in femoral stem design has grown increasingly popular over the last decade because of the theoretical advantage of more flexibility and optimization of femoral anteversion, limb length, and femoral component offset. With the benefit of increased surgical flexibility, however, modularity also carries the theoretical risks of fretting at the modular surfaces, sequelae ...

متن کامل

Mixed Mode Fracture Analysis of Multiple Interface Cracks

This paper contains a theoretical formulation of multiple interface cracks in two bonded dissimilar half planes subjected to in-plane traction. The distributed dislocation technique is used to construct integral equations for a dissimilar mediums weakened by several interface cracks. These equations are of Cauchy singular type at the location of dislocation, which are solved numerically to obta...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 19  شماره 7

صفحات  173- 186

تاریخ انتشار 2008-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023