Calibration curves for on-line leakage detection using radiotracer injection method

نویسندگان

  • Ayoub Khatooni Department of Radiation Application, Shahid Beheshti University
چکیده مقاله:

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive tracer. After calibration of radiation detectors, the amount of leakage can be calculated based on the count difference of detectors. Also, the effect of material and thickness and diameter of pipe, crystal dimension, types of fluid, activity of tracer and its type (24Na, 82Br, 131I, 99mTc, 113mIn) as well as have been investigated on the detectable amount of leakage. According to the results, for example, leakage more than 0.007% in volume of the inlet fluid for iron pipe with outer diameter 4 inch and thickness of 0.5 cm, Petrol as fluid inside pipe, 3 3 inch detector and 24Na with activity of 100 mCi can be detected by this presented method.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A descent method for explicit computations on curves

‎It is shown that the knowledge of a surjective morphism $Xto Y$ of complex‎ ‎curves can be effectively used‎ ‎to make explicit calculations‎. ‎The method is demonstrated‎ ‎by the calculation of $j(ntau)$ (for some small $n$) in terms of $j(tau)$ for the elliptic curve ‎with period lattice $(1,tau)$‎, ‎the period matrix for the Jacobian of a family of genus-$2$ curves‎ ‎complementing the classi...

متن کامل

Using Moiré Chroma for DSC On-line Focus Calibration

Focus is an important part before capturing an image by DSC. After obtaining an optimized focus, image can have best contrast to evaluate. So far, many focus methods were built and they include maximum contrast search and object distance inverse calculation. No mater which method is used, both can provide us best focus to capture. In this paper, another method to determine focus is moiré. Reaso...

متن کامل

Gas injection membrane extraction for fast on-line analysis using GC detection.

Membrane extraction has been interfaced with gas chromatography and mass spectroscopy for the analysis of volatile organics in water. The vacuum in a mass spectrometer provides fast mass transport. The time required to complete permeation in a GC interface can be fairly long, because the positive pressure of the carrier gas on the permeate side slows down the analyte permeation. The aqueous bou...

متن کامل

islanding detection methods for microgrids

امروزه استفاده از منابع انرژی پراکنده کاربرد وسیعی یافته است . اگر چه این منابع بسیاری از مشکلات شبکه را حل می کنند اما زیاد شدن آنها مسائل فراوانی برای سیستم قدرت به همراه دارد . استفاده از میکروشبکه راه حلی است که علاوه بر استفاده از مزایای منابع انرژی پراکنده برخی از مشکلات ایجاد شده توسط آنها را نیز منتفی می کند . همچنین میکروشبکه ها کیفیت برق و قابلیت اطمینان تامین انرژی مشترکان را افزایش ...

15 صفحه اول

Camera Calibration Using Line Correspondences

In this paper, a method of determining the essential matrix for uncalibrated cameras is given, based on line matches in three images. The three cameras may have different unknown calibrations, and the essential matrices corresponding to each of the three pairs of cameras may be determined. Determination of the essential matrix for uncalibrated cameras is important, forming the basis for many al...

متن کامل

Model-based leakage detection in a pulverized coal injection vessel

A method for detecting and isolating incipient leakages in the valves of a pulverized coal injection vessel for a blast furnace process is presented. Nonlinear physical gray-box models of the plant are developed. Values of the unknown parameters are estimated by identification. Observers are constructed for these models and the residuals are used in a generalized likelihood ratio test. The meth...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 17  شماره 4

صفحات  634- 634

تاریخ انتشار 2017-11

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023