Bremsstrahlung imaging from the liver using the Monte Carlo simulation

نویسندگان

  • Rajabi, Hossein Dept. of Medical Physics, Faculty of Medicine, Tarbiat Modares University, Tehran, Iran
  • Taleshi Ahangari, Hadi Dept. of Medical Physics, Faculty of Medicine,Semnan University of Medical Sciences, Semnan, Iran
چکیده مقاله:

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the images and the quantization validation of the images cannot be performed. Therefore, the accuracy of scatter correction methods is of great importance. The method involves the use of energy window, empirically selected broad bremsstrahlung energy to enhance the signal to noise ratio and a wiener restoration filter to compensate for system blur. Materials and Methods: To simulate and validate the system, a water bottle containing Phosphorus-32 (P32) radio was taken. GATE package was used to determine the spectrum of bremsstrahlung radiation from P32 inside the liver and Zubal phantom was used to model a liver. Importantly, simulations were performed in the presence of a collimator without collimator and the collimator function was calculated. Zubal Phantom was also used to model liver imaging. The Wiener filter was used as a resolution adjuster. Results: Despite the small number of electrons reaching the collimator, a considerable spectrum is produced. Collimator function and simulated liver image were calculated. No significant change in resolution was observed after using the Weiner filter. Conclusion: The energy spectrum of the beams was altered after collimation to the collimator. Also, the shape of the energy spectrum was influenced by the type of tissue and size of the patient. The results had shown that planar gamma camera imaging and quantitation of P32 can be done. There is no compelling reason to suggest that the Wiener filter is useful in planning a Plane.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF

The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...

متن کامل

Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

متن کامل

Comparison of TOF-PET and Bremsstrahlung SPECT images of Yttrium-90: A Monte Carlo Simulation Study

Objective(s): Yttrium-90 (90Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90Y using Monte Carlo simu...

متن کامل

Monte Carlo Simulation using Excel

A Monte-Carlo Simulation using Excel Spreadsheet has been used to determine the reliability of a geothermal power plant. This simulation technique utilizes the powerful mathematical and statistical capabilities of Excel. Simulation time is dependent on the complexity of the system, computer speed and the accuracy desired, so a simulation may range from a few minutes to a few hours.

متن کامل

Simulation of Temperature Distribution in a Continuous Tunnel Reheat Furnace Using the Monte Carlo Method

A mathematical model of a continuous reheating furnace has been developed to identify the design and operating parameters that significantly affect furnace performance. In this study, the furnace is modeled 3 dimensionally and theMonte Carlomethod is used to find the overall absorption factor. The overall absorption factor is then used to calculate the energy balance for furnace walls, the gas,...

متن کامل

Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 22  شماره 3

صفحات  497- 504

تاریخ انتشار 2020-05

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023