Biological Activity Analysis of Native and Recombinant Streptokinase Using Clot Lysis and Chromogenic Substrate Assay
نویسندگان
چکیده مقاله:
Determination of streptokinase activity is usually accomplished through two assay methods: a) Clot lysis, b) Chromogenic substrate assay. In this study the biological activity of two streptokinase products, namely Streptase®, which is a native product and Heberkinasa®, which is a recombinant product, was determined against the third international reference standard using the two forementioned assay methods. The results indicated that whilst the activity of Streptase® was found to be 101 ± 4% and 97 ± 5% of the label claim with Clot lysis and Chromogenic substrate assay respectively, for Heberkinasa® the potency values obtained were 42 ± 5% and 92.5 ± 2% of the label claim respectively. To shed some light on the reason for this finding, the n-terminal sequence of the streptokinase molecules present in the two products was determined. The results showed slight differences in the amino acid sequence of the recombinant product in comparison to the native one at the amino terminus. This finding supports those of other workers who found that n-terminal sequence of the streptokinase molecule can have significant effect on the activity of this protein.
منابع مشابه
biological activity analysis of native and recombinant streptokinase using clot lysis and chromogenic substrate assay
determination of streptokinase activity is usually accomplished through two assay methods: a) clot lysis, b) chromogenic substrate assay. in this study the biological activity of two streptokinase products, namely streptase®, which is a native product and heberkinasa®, which is a recombinant product, was determined against the third international reference standard using the two forementioned a...
متن کاملBiological Activity Analysis of Native and Recombinant Streptokinase Using Clot Lysis and Chromogenic Substrate Assay
DETERMINATION OF STREPTOKINASE ACTIVITY IS USUALLY ACCOMPLISHED THROUGH TWO ASSAY METHODS: a) Clot lysis, b) Chromogenic substrate assay. In this study the biological activity of two streptokinase products, namely Streptase®, which is a native product and Heberkinasa®, which is a recombinant product, was determined against the third international reference standard using the two forementioned a...
متن کاملDetermination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....
متن کاملDetermination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study
Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....
متن کاملpatterns and variations in native and non-native interlanguage pragmatic rating: effects of rater training, intercultural proficiency, and self-assessment
although there are studies on pragmatic assessment, to date, literature has been almost silent about native and non-native english raters’ criteria for the assessment of efl learners’ pragmatic performance. focusing on this topic, this study pursued four purposes. the first one was to find criteria for rating the speech acts of apology and refusal in l2 by native and non-native english teachers...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 11 شماره 4
صفحات 1087- 1093
تاریخ انتشار 2012-07-21
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023