Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
نویسندگان
چکیده مقاله:
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled with 5.9 kBq/mL 18F-FDG to characterize normal lung tissues as a phantom. The PET/CT images of the phantom were acquired at rest. Then, the barrel was moved periodically to simulate breathing while acquiring PET/CT data. Volume recovery coefficient (VRC) was applied to evaluate the accuracy of ITVs. For statistical analysis, paired t-test and analysis of variance were applied. Results: The VRCs ranged from 0.74 to 0.98 and significantly varied among gross tumor volumes for delineating ITV (P0.05), whereas VRC decreased with increasing distance in three-dimensional PET scans (P
منابع مشابه
background-based delineation of internal tumor volumes on static positron emission tomography in a phantom study
objective(s): considering the fact that the standardized uptake value (suv) of a normal lung tissue is expressed as x±sd, x+3×sd could be considered as the threshold value to outline the internal tumor volume (itv) of a lung neoplasm. methods: three hollow models were filled with 55.0 kbq/ml fluorine18- fluorodeoxyglucose (18f-fdg) to represent tumors. the models were fixed to a barrel filled w...
متن کاملBackground-based Delineation of Internal Tumor Volume in Static Positron Emission Tomography in a Phantom Study
OBJECTIVES Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. METHODS Three hollow models were filled with 55.0 kBq/mL fluorine-18 fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled wit...
متن کاملRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملAccurate automatic delineation of heterogeneous functional volumes in positron emission tomography for oncology applications.
PURPOSE Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. METHODS ...
متن کاملThe effect of fasting on Positron Emission Tomography (PET) imaging
As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...
متن کاملA Comparative Study of the Construction of Positron Emission Tomography/Computed Tomography Facilities in Three South African Hospitals
Introduction: Development of higher energy modalities such as positron emission tomography/computed tomography (PET/CT), has led to more complex shielding problems. This is due to several factors, such as the radiopharmaceutical relatively high-administered activity, high patient throughput, and high energies of 511 kilo-electron volt (keV) positron annihilation photon...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید