Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

نویسندگان

  • Alireza Karimian Department of Biomedical Engineering - Faculty of Engineering- University of Isfahan
  • Iraj Jabbari Department of nuclear Engineering, Faculty of new science and technologies, University of Isfahan, Isfahan, Iran
  • zahra kavousi Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran
چکیده مقاله:

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector element sizes, scintillator material, impurities in the scintillator material, and the material of detector separators on X-ray crosstalk. Materials and Methods: This study was performed using Monte Carlo simulation. In the first step, X-ray tube and its energy spectrum at the energies of 80, 100, 120, and 140 keV were simulated and validated by using SpekCalc and t-test. Then, other important parts of CT scanner, namely filters, detectors, and grids were simulated. X-ray crosstalk between CT detectors was calculated in air and in the presence of water phantom (as a simulator of human body) to compare the effect of scattered photons. Finally, the influence of some important parameters on X-ray crosstalk was evaluated. Results: In CT scanner with small elements, when using phantom, crosstalk increases by 16-50%. Using the lowest possible energies of X-ray, decreases the crosstalk up to 43% of its initial amount. Furthermore coating a 10 or 20 µm layer of tungsten or lead on the detector separators, decreases the X-ray crosstalk significantly. Conclusion: Choosing the proper high voltage, detectors’ material and its dimensions, scintillator impurities and septa material can decrease X-ray crosstalk.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo simulation of a computed tomography x-ray tube.

The dose delivered to patients during computed tomography (CT) exams has increased in the past decade. With the increasing complexity of CT examinations, measurement of the dose becomes more difficult and more important. In some cases, the standard methods, such as measurement of the computed tomography dose index (CTDI), are currently under question. One approach to determine the dose from CT ...

متن کامل

Characterization of X-Ray Diamond Detector by Monte Carlo Method

The use of diamond as material for X-ray detector is subject of investigation and practice in radiotherapy, space and material science and technology. This paper presents the results of application of Monte Carlo method for simulation of photon transport through diamond detector. The aim is restitution and demonstrating of numerical technique for characterization of electrical properties for di...

متن کامل

An iterative method to estimate x-ray attenuation coefficients in computed tomography

Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry

X-ray fluorescence computed tomography (XFCT) based on sheet beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper, polychromatic X-ray fluorescence computed tomography with sheet-beam geometry is tested by Monte Carlo simulation. First, two phantoms (A and B) filled...

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره 3

صفحات  169- 175

تاریخ انتشار 2018-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023