Assessment of the diagnostic value of urine protein content in 8- and 16-hour samples with 24-hour urine protein sample in hospitalized women with pre-eclampsia in 2016

نویسندگان

  • Ahmadi, Maryam Department of Obstetrics and Gynaecology, Faculty of Medicine, Hamedan University of Medical Sciences, Hamedan, I. R. Iran.
  • Daneshyar, Sajjad Student Researcher Committee, Hamedan University of Medical Sciences, Hamedan, I. R. Iran.
چکیده مقاله:

Background: High blood pressure disorders are common in pregnancy. The combination of high blood pressure and proteinuria in pregnancy, or pre-eclampsia, dramatically increases the risk of death and perinatal complications. Nevertheless, 24-hour urine protein sample is still a gold standard. This study aimed to determine and compare the diagnostic value of 8- and 16-hour urine protein samples with that of 24-hour urine protein sample. Material and Methods: This cross-sectional study was performed on 92 pregnant women with hypertension and gestational age greater than 20 weeks who were evaluated for proteinuria and rejection of pre-eclampsia and 92 pregnant women with gestational age greater than 20 weeks and normal blood pressure. All patients had been admitted to the women's ward of Imam Reza Hospital in Kermanshah. Three consecutive 8-hour samples were collected from each patient, and the protein was sampled at 8, 16 and 24 hours. Results: Correlation coefficient between 16- and 24-hour urine protein samples was 0.832 (the highest correlation coefficient), which showed a strong correlation between 16- and 24-hour urine protein samples. The correlation coefficients of urine protein between the first and third 8-hours were 0.621 and 0.528, respectively, which showed a moderate correlation with 24-hour urine protein. Urine protein for the first 16 hours had a high efficacy rate of 96.3% and negative predictive value of 97.5% in diagnosis of non-patient cases. However, due to the sensitivity of 82.6%, there was no definitive value in detecting abnormal cases. Conclusion: The negative result of the first 16-hour urine protein can have a significant effect on rejection of pre-eclampsia in hospitalized or outpatient patients.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COMPARATIVE EVALUATION OF QUANTITATIVE PROTEIN MEASUREMENTS IN 8-12 AND 24 HOUR URINE SAMPLES FOR DIAGNOSIS OF PRE-ECLAMPSIA

 ABSTRACT Background: In this study our purpose was to determine whether 8 and/or 12 hour urine total protein values correlate with the 24 hour value to confirm the diagnosis of pre-eclampsia. Methods: The study population included 70 inpatients with hypertensive disorders of pregnancy. Patient's urine was collected over 24 hours with the first 8 hours, next 4 hours, and remaining 12 hours in s...

متن کامل

comparative evaluation of quantitative protein measurements in 8-12 and 24 hour urine samples for diagnosis of pre-eclampsia

abstract background: in this study our purpose was to determine whether 8 and/or 12 hour urine total protein values correlate with the 24 hour value to confirm the diagnosis of pre-eclampsia. methods: the study population included 70 inpatients with hypertensive disorders of pregnancy. patient's urine was collected over 24 hours with the first 8 hours, next 4 hours, and remaining 12 hours in se...

متن کامل

correlation of 2 hour, 4 hour, 8 hour and 12 hour urine protein with 24 hour urinary protein in preeclampsia.

objective: to find shortest and reliable time period of urine collection for determination of proteinuria. materials and methods: it is a prospective study carried out on 125 pregnant women with preeclampsia after 20 weeks of gestation having urine albumin >1 using dipstick test. urine was collected in five different time intervals in colors labeled containers with the assistance of nursing sta...

متن کامل

Correlation of 2 Hour, 4 Hour, 8 Hour and 12 Hour Urine Protein with 24 Hour Urinary Protein in Preeclampsia

OBJECTIVE To find shortest and reliable time period of urine collection for determination of proteinuria. MATERIALS AND METHODS It is a prospective study carried out on 125 pregnant women with preeclampsia after 20 weeks of gestation having urine albumin >1 using dipstick test. Urine was collected in five different time intervals in colors labeled containers with the assistance of nursing sta...

متن کامل

Comparative Evaluation of Quantitative Protein Measurements in 8-12 and 24 Hour Urine Samples for Diagnosis of Pre-eclampsia

Background: In this study our purpose was to determine whether 8 and/or 12 hour urine total protein values correlate with the 24 hour value to confirm the diagnosis of pre-eclampsia. Methods: The study population included 70 inpatients with hypertensive disorders of pregnancy. Patient's urine was collected over 24 hours with the first 8 hours, next 4 hours, and remaining 12 hours in separate co...

متن کامل

A Comparison of 4- and 24-Hour Urine Samples for the Diagnosis of Proteinuria in Pregnancy

Background: Preeclampsia is a serious complication of pregnancy, and it is vital to diagnosis the condition as early as possible. Proteinuria is an important symptom of preeclampsia, and repeated urine analysis to screen for the condition is part of the standard antenatal care. The purpose of this study was to determine the correlation between 4- and 24-hour urine total protein values to examin...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 23  شماره 3

صفحات  280- 285

تاریخ انتشار 2019-05

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023