Assessment of Patient Dose from CT Examinations in Khorasan, Iran

نویسندگان

  • Mohammad Bahrami Department of Medical Physics, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
  • Mohammad Taghi Bahreyni Toossi Medical Physics Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran Department of Medical Physics, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
چکیده مقاله:

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two reference dose quantities have been defined in order to promote the use of good technique in CT. These are weighted CT dose index (CTDIw) in (mGy) for a single slice in serial scanning or per rotation in helical scanning, and dose–length product (DLP) per complete examination (mGy.cm), All measurements were performed using a pencil shaped ionization chamber introduced into polymethyl methacrylate cylindrical brain and body phantoms. This survey was performed on 7 CT scanners in Khorasan Province-Iran. Results DLP for brain, chest, abdomen and pelvic examinations had a range of 255 - 1026, 76-1277, 48-737, 69-854 mGy.cm, respectively. Conclusion The results obtained in this study show that the DLP values obtained in this province are lower than European Commission reference dose levels (EC RDL), in other words performance of all the scanners were satisfactory.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

assessment of patient dose from ct examinations in khorasan, iran

introduction computed tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. materials and methods two refe...

متن کامل

Patient dose resulting from CT examinations in Yazd, Iran

Background: With the introduction of computed tomography in diagnostic radiology a new and fundamentally different imaging modality has become available. Meanwhile, it is clear that the absorbed doses by the patients during CT were relatively high in comparison with those of other diagnostic radiology techniques. The aim of this survey was to determine the average absorbed dose in Yazd provin...

متن کامل

patient dose resulting from ct examinations in yazd, iran

background: with the introduction of computed tomography in diagnostic radiology a new and fundamentally different imaging modality has become available. meanwhile, it is clear that the absorbed doses by the patients during ct were relatively high in comparison with those of other diagnostic radiology techniques. the aim of this survey was to determine the average absorbed dose in yazd province...

متن کامل

Assessment of dose reduction and influence of gantry rotation time in CT abdomen examinations

Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...

متن کامل

Assessment of Patient Dose in CT

This report summarises work undertaken in support of a European Commission (EC) Concerted Action on CT that has included both a review and further development of the framework for CT dosimetry. The system previously established by the EC for reference doses in CT (with the quantities weighted CTDI (CTDIw) and dose-length product (DLP)) has been expanded to include subsequent developments in CT ...

متن کامل

Patient dose in routine X-ray examinations in Yazd state

Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 4

صفحات  233- 238

تاریخ انتشار 2012-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.