Assessment of dose reduction and influence of gantry rotation time in CT abdomen examinations

نویسندگان

  • A. Sulieman Radiology and Medical Imaging Department, Prince Sattam bin Abdulaziz University, Alkharj, Saudi Arabia
  • M.K. Saeed Department of Radiological Sciences, Najran University, Najran, Saudi Arabia
  • N. Tammam Physics Department, College of Sciences, Princess Nourah Bint Abdulrahman University, Riyadh,  Saudi Arabia  
چکیده مقاله:

Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: the first category as control category (80 patients), and the other as optimisation category (48 patients). The optimisation protocol was based on decreasing the gantry rotation time. Results: In general, the faster gantry rotation times (0.7 s/rot and 0.5 s/rot) resulted in dose reduction while maintaining images noise within the acceptable range. After dose optimization, the overall cancer risk was reduced by 21%, 49%, 29%, and 16%, for the patients undergoing abdominal examinations on 2, 4, 16 and 64 slice CT scanners, respectively. Conclusion: The patient dose optimisation during CT abdomen was investigated. By lowering gantry rotation time, a radiation dose reduction of up to 30 % was achieved without compromising the diagnostic findings. Accordingly, the attention of all technologists necessary to take advantage of the dose reduction methods reported in this study.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Patient Dose from CT Examinations in Khorasan, Iran

Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two refe...

متن کامل

Rotation Time and Dose Reduction in Chest CT scans

Computed tomography is associated with exposing patients with high radiation doses. This study was conducted to evaluate the effect of reducing the rotation time to reduce the dose without compromising the image quality. Two types of CT scanners were involved in this study: a 4-slice and a 16-slice scanner. A significant reduction in CTD Ivol and DLP were observed with the 4-slice scanner, with...

متن کامل

Measurement of gantry rotation time in modern ct

The purpose of this study was to develop and evaluate a noninvasive method to assess rotation time in modern commercial computed tomography (CT) systems. The rotation time was measured at a selected nominal rotation time (400 ms) utilizing two types of solid-state detectors: the RTI's CT Dose Profiler (CTDP) and Unfors' Xi (Xi) probes. Either CTDP or Xi was positioned on the inner cover of the ...

متن کامل

synthesis of 3-aryl-2h-benzo[b]-1,4-oxazines in [omim]bf4 and reduction of organic compounds in methylimidazolium formate

در این پروژه ترکیبات 3-آریل-2h-بنزو[b]-4،1-اکسازین ها از مواد اولیه تجاری مشتقات دو آمینو فنول و ?-هالو کتون های آروماتیک در مایع یونی 1-اکتیل-3-متیل ایمیدازولیوم تترا فلورو بورات([omim]bf4) سنتز شده است. این واکنش توسط باز پتاسیم کربنات محلول از طریق o-آلکیلاسیون و سپس یک واکنش آمیداسیون درون مولکولی خود بخود در مدت زمان کوتاه انجام می شود. ترکیبات 4،1-بنزوکسازین به این روش با بهره خوب تا آلی ...

15 صفحه اول

assessment of deep word knowledge in elementary and advanced iranian efl learners: a comparison of selective and productive wat tasks

testing plays a vital role in any language teaching program. it allows teachers and stakeholders, including program administrators, parents, admissions officers and prospective employers to be assured that the learners are progressing according to an accepted standard (douglas, 2010). the problems currently facing language testers have both practical and theoretical implications but the first i...

assessment of patient dose from ct examinations in khorasan, iran

introduction computed tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. materials and methods two refe...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 19  شماره 1

صفحات  223- 230

تاریخ انتشار 2021-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023