An Improved Transformerless Grid-Connected PV System With Related Control Strategy to Reduce Leakage Current, Extract Maximum Power Point and Control Power
نویسندگان
چکیده مقاله:
The main purposes of a transformerless grid-connected photovoltaic (PV) system consist of the reduction of leakage current, extraction of maximum power point (MPP), tracking of MPP (MPPT), controlling the active and reactive powers, and having the unity power factor. To achieve the above-mentioned aims, the following actions have been performed in this paper. First of all, a brief analysis of the transformerless PV system has been done by using the conventional full-bridge (FB) topologies with two bipolar and unipolar PWM techniques. Then, an effective solution has been also introduced to significantly reduce the leakage current in the conventional H5 FB topology. Moreover, a proper control method has been proposed by using the combination of the fractional open-circuit voltage (FOCV) and the model predictive control (MPC) strategies to extract the MPP from PV panels, control the injection of the reactive power to the gird and have the unity power factor. At last, the simulation results performed in PSCAD software will be used to prove the correct performance of the proposed control method in the improved H5 FB topology.
منابع مشابه
A Grid Connected Transformerless Inverter and its Model Predictive Control Strategy with Leakage Current Elimination Capability
This paper proposes a new single phase transformerless Photovoltaic (PV) inverter for grid connected systems. It consists of six power switches, two diodes, one capacitor and filter at the output stage. The neutral of the grid is directly connected to the negative terminal of the source. This results in constant common mode voltage and zero leakage current. Model Predictive Controller (MPC) tec...
متن کاملA Novel Control Strategy for a Single-phase Grid-connected Power Injection System
In this paper, a novel and simple control strategy, based on state feedback method is suggested to control the power injection system (PIS). The considered PIS is composed of, a DC voltage source, a voltage source inverter (VSI) and a L-C-L filter. The DC source includes the battery source with boosted voltage. The battery can be charged with photovoltaic cells. Since, the grid voltage acts as ...
متن کاملDesign of A Single-Phase Transformerless Grid-Connected PV Inverter Considering Reduced Leakage Current and LVRT Grid Codes
A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...
متن کاملVoltage Oriented Control Applied to a Grid Connected Photovoltaic System with Maximum Power Point Tracking Technique
Problem statement: This study presented a grid connected photovoltaic system with voltage oriented control. This system contains the problem of degradation of photovoltaic power with climatic factors and the problem of synchronization of currents to be injected to the grid. Approach: In order to optimize the photovoltaic energy generation, we developed a new maximum power point tracking algorit...
متن کاملMaximum Power Point Tracking Controller Connecting PV System to Grid
The photovoltaic generators have a nonlinear V-I characteristics and maximum power points which vary with the illumination level and temperature. Using maximum power point tracker(MPPT) with the intermediate converter can increase the system efficiency by matching the PV systems to the load. This paper presents a maximum power point tracker based on fuzzy logic and a control scheme for a single...
متن کاملVoltage-Based Maximum Power Point Tracking Control of PV System
C, Ca Filter, array capacitance d1, d2 Duty ratios of switch S1,S2 DP1, DP2 Diodes of individual boost cells IA SCA current IAb SCA current with boost converter IAd SCA current with IDB converter Im SCA current at maximum power operation Iab Average load current with boost converter Iaid Average load current with IDB converter Iph Insolation dependent photo current I0 Cell reverse saturation cu...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 16 شماره 4
صفحات 513- 523
تاریخ انتشار 2020-12
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023