Absorbed dose of Fetus in SPECT-CT Imaging of Mother's Abdomen Regions using Monte Carlo method

نویسندگان

چکیده مقاله:

SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period before birth, there may be harmful and irreversible effects on the fetus; therefore protecting the pregnant woman and the fetus against radiation is of great importance. The purpose of this study is to evaluate and calculate the fetus absorption dose in cardiac imaging using the SPECT-CT machine in stress and resting conditions of the cardiac by injecting 20 mCi of radiopharmaceutical of 99mTc-MIBI.  In order to evaluate the fetus absorption dose, the Monte Carlo method, using the MCNPX code and the ORNL phantom, was applied to simulate the fetus in three, six and nine months of pregnancy, and the radiation absorbed doses of fetus absorption were calculated in two condition of stress and rest. The absorbed dose of fetus in stressed state in three, six and nine months of gestational age are 1.26 × 10-2, 2.9 × 10-3, 2.83 × 10-4  mGy respectively and The fetus absorption dose in rest in three, six and nine months of gestational age are  2.52 × 10-2, 5.79 × 10-3, 5.68 × 10-4 mGy respectively. The results of this study indicate that the highest fetus absorption dose is related to cardiac resting imaging at the third month of the fetus. The fetus absorption dose has been calculated to be less than 0.05 Gy for all maintenance periods, which, according to the NCRP 128 and ICRP 84, do not cause a serious risk to the fetus. However, special immunological advices should also be given to pregnant women to reduce the absorption of fetus, especially in the early months of pregnancy.    

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

متن کامل

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

متن کامل

Measurement of organ dose in chest CT examination using Monte Carlo simulation

Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...

متن کامل

Measurement of organ dose in abdomen-pelvis CT exam as a function of mA, KV and scanner type by Monte Carlo method .

Background: CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in CT exams is very important. While methods to calculate the effective dose have been established (ICRP 26 and ICRP 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the CT procedure. However, dete...

متن کامل

Assessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method

Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  223- 228

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023