Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), and sodium tetraphenylborate (NaTPB, 1.1%). The electrode exhibited a constant sensitivity of 30.20 ± 0.5 mV to VO2+ ions over a concentration range of 5 mM to 1 mM. The detection limit was calculated to be 5 mM with a response time of less than 35 s. The electrode showed to be highly reproducible over a period of 3 weeks. This sensor exhibits high selectivity to VO2+ ions and was successfully employed for potentiometric titration of VO2+ ions with EDTA.
منابع مشابه
a novel carbon paste electrode for potentiometric determination of vanadyl ion
carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (vo2+) in aqueous medium. the new ligand was synthesized in three steps with high yield. the optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), and sodium tetra...
متن کاملCOBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID
A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...
متن کاملChemically Modified Carbon Paste Electrode for Determination of Cesium Ion by Potentiometric Method
A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyanoferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) ions over a wide concentration range from 1 × 10 to 1 × 10 mol·L with a slope of 58 ± 0.5 mV·decade. It has a response time of about 35 s and can be used for a period of 3 months with...
متن کاملIon Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation
Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...
متن کاملMultiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods
A chemically modified carbon paste electrode with multiwall carbon nanotube (MWCNT) was prepared and used as a sensor for Cu2+ ion. The unique chemical and physical properties of CNT have paved the way to new and improved sensing devices. A central composite chemometrics design was applied for multivariate optimization of the effects of three significant parameters (...
متن کاملcobalt phthalocyanine modified carbon paste electrode as a potentiometric sensor for determination of ascorbic acid
a carbon paste electrode modified with cobalt (ii) phthalocyanine (copc) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. the potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 m (?1- 1800 µg ml ) with a nernstian slope of 56 mv at ph 7. the limit of detection was 0.2 µg ml ascor...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 34 شماره 4
صفحات 89- 96
تاریخ انتشار 2015-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023