A Comprehensive Model for Stiffness Coefficients in V-Shaped Cantilevers

نویسندگان

  • A. H. Korayem Robotic Research Laboratory, Center of Excellence in Experimental Solid Mechanics and Dynamics, School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, I. R. Iran
  • A. K. Hoshiar Faculty of Industrial and Mechanical Engineering, Islamic Azad University, Qazvin Branch, Qazvin, I. R. Iran
  • M. H. Korayem Robotic Research Laboratory, Center of Excellence in Experimental Solid Mechanics and Dynamics, School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, I. R. Iran
  • S. Badrlou Robotic Research Laboratory, Center of Excellence in Experimental Solid Mechanics and Dynamics, School of Mechanical Engineering, Iran University of Science and Technology, Narmak, Tehran, I. R. Iran
چکیده مقاله:

   During past decade the AFM based nanomanipulation has been focus of attention as the promising nano fabrication approach. The main challenge in this process is the real-time monitoring. Consequently, the dynamic models have been proposed as a solution to the existing challenge. In the modeling approach the magnitudes of the forces are proportional to the stiffness coefficients of cantilevers. The precise calculation of these coefficients has been introduced in numerous works. The proposed stiffness coefficients for the V-shaped cantilevers fail to present in all commercial cantilever geometry. The geometrical deviation has a considerable impact on the magnitude of stiffness coefficients. Therefore, in this paper the existing model has been modified to include the commercial cantilever and take into account the effect of geometry variation. FEM simulation has been used to investigate the effect of geometry change and the results of these simulations have been exerted to the model which resulted in proposed comprehensive model. The proposed new stiffness model covers a wide range of commercial V-shape cantilevers and makes the process more practical.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

GDQEM Analysis for Free Vibration of V-shaped Atomic Force Microscope Cantilevers

V-shaped and triangular cantilevers are widely employed in atomic force microscope (AFM) imaging techniques due to their stability. For the design of vibration control systems of AFM cantilevers which utilize patched piezo actuators, obtaining an accurate system model is indispensable prior to acquiring the information related to natural modes. A general differential quadrature element method (...

متن کامل

Parallel beam approximation for V-shaped atomic force, microscope cantilevers

Due to its simplicity, the parallel beam approximation (PBA) is commonly used in the analytical evaluation of the spring constant of V-shaped atomic force microscope (AFM) cantilevers. However, the point of contention regarding the validity of the PBA is as yet an unresolved issue, which has been exacerbated by some recent contradictory reports. In this paper, we present a detailed investigatio...

متن کامل

gdqem analysis for free vibration of v-shaped atomic force microscope cantilevers

v-shaped and triangular cantilevers are widely employed in atomic force microscope (afm) imaging techniques due to their stability. for the design of vibration control systems of afm cantilevers which utilize patched piezo actuators, obtaining an accurate system model is indispensable prior to acquiring the information related to natural modes. a general differential quadrature element method (...

متن کامل

Resistance to Flow in a V-Shaped Bottom Channel

Water flow in open channels is always subject to the resistance to flow and energy dissipation. For design purposes, one of the needed variables is the hydraulic resistance coefficient. For this mean, the influence of cross-sectional shape together with secondary flow cells and lateral distribution of true boundary shear stress have not yet been fully explored. This paper surveys the number of ...

متن کامل

comprehensive performance study of magneto cantilevers as a candidate model for biological sensors used in lab-on-a-chip applications

in recent years, demand for biological sensors which are capable of fast and accurate detection of minor amounts of pathogens inreal‑time form has been intensified. acoustic wave (aw) devices whose performance is determined by mass sensitivity parametersand quality factor are used in biological sensors as platforms with high quality. yet, current aw devices are facing many challengessuch as the...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 12  شماره 1

صفحات  27- 36

تاریخ انتشار 2016-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023