A comparative study on soleus H reflex parameters using vertebral column and peripheral nerve stimulation
نویسندگان
چکیده مقاله:
Although low-threshold transcutaneous electrical nerve stimulation (TENS) is a modality used for control of pain, but its effect in the control of spasticity and change of excitability of a motor neuron is controversial. Therefore, this study was conducted to evaluate the effects of 15-min tripolar TENS of vertebral column and bipolar TENS of common peroneal nerve (300 µs width, 50 Hz) on synaptic activities of spinal cord. For this purpose, soleus H-reflex, Mh wave (M wave on the H-reflex signal) and M wave parameters were studied. Twelve healthy and non-athletic female volunteers were tested in two groups. First group received vertebral column stimulation and second group received peripheral stimulation in 4 separate experimental sessions (two control and two test sessions). In the first group, tripolar TENS (cathode on T 11, one anode 3 cm above and the other 7 cm below the cathode) was applied. In the second group, bipolar TENS (cathode on common peroneal nerve at the level of fibular head and anode 3 cm below the cathode) was used. Then, the acquired data were analyzed statistically. The results showed that peak to peak amplitude (PP), area under the curve and average rectified value (ARV) of H-reflex in the first stimulation group decreases (p<0.05), but in the second group, there is no significant changes. In addition, these parameters increased for Mh wave in the first group, but in the second group, there were no significant changes. It is suggested that tripolar TENS of vertebral column has augmented activity of the fast motor units. In this respect, it is possible that Renshaw cells are more activated and suppressed the activity of the slow motor units. These effects tended to increase the sensitivity of soleus motor end plate and decrease H-reflex amplitude. It can be concluded that tripolar TENS of vertebral column (depending on the site and method of stimulation) appears to be effective in synaptic activities of the spinal cord, especially the fast motor units and Renshaw cells, while bipolar TENS of common peroneal nerve does not produce such effect.
منابع مشابه
The effects of vertebral column tripolar electrical stimulation with various intensities on soleus and gastrocnemius H-reflex and Mh wave recruitment curve
Abstract: To assess the effect of penetration depth of the surface tripolar electrical stimulation, Tripolar TENS was applied with different intensities (equal to sensory threshold (ST), 1.25 ST, 1.5 ST) on vertebral column of twenty healthy and three hemiplegic subjects. The cathode of TENS was laid on the T11 vertebra and anodes were put 3cm apart from cathode, longitudinally and in the anod...
متن کاملSoleus H-reflex to S1 nerve root stimulation.
H-reflexes in normals were elicited by percutaneous electrical and magnetic stimulation of proximal nerve roots at the cauda equina. H-M interval to S1 nerve root stimulation at the level of the S1 foramen was 6.8 +/- 0.33 ms, with side to side difference of 0.16 +/- 0.13 ms. Compression/ischemia of the sciatic nerve in the mid-thigh abolished the H-reflex to stimulation of the tibial nerve at ...
متن کاملEffects of tripolar TENS of vertebral column on slow and fast motor units: A preliminary study using H-reflex recovery curve method
Introduction: Effect of tripolar TENS of vertebral column on slow and fast motoneurons (MNs) activity of soleus muscle was previously investigated. In this study for better differentiation of the behavior of slow and fast MNs, we exploited H-reflex recovery curve recording in two muscles of soleus and lateral gastrocnemius, respectively as the representatives of slow and fast muscles. Meth...
متن کاملthe effect of tripolar cathodal stimulation of vertebral column on the h-reflex depression in the spinal cord injury patients
background and aim: the normal response of h-reflex depression (hd) was reduced in chronic spinal cord injury (sci) patients. the reduction of this normal response can lead to increase the muscle tone and spasticity. the purpose of this study is to investigate the effect of tripolar cathodal stimulation on hd in sci patients. materials and methods: this study was conducted in 10 volunteered s...
متن کاملEvaluation of H-reflex recruitment curve after application of TENS on the desensitised skin of vertebral column
Electrical stimulation of neuromuscular system has been used in a variety of research and therapeutic applications. Although tri-polar transcutaneous electrical stimulation (TENS) is commonly used to change motoneuron excitabi1ity, but the effect of TENS on synaptic activities through dorsal column stimulation or cutaneous pathways is unknown. So, the aim of this research study was to determine...
متن کاملeffects of tripolar tens of vertebral column on slow and fast motor units: a preliminary study using h-reflex recovery curve method
introduction: effect of tripolar tens of vertebral column on slow and fast motoneurons (mns) activity of soleus muscle was previously investigated. in this study for better differentiation of the behavior of slow and fast mns, we exploited h-reflex recovery curve recording in two muscles of soleus and lateral gastrocnemius, respectively as the representatives of slow and fast muscles. methods: ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 6 شماره None
صفحات 91- 98
تاریخ انتشار 2002-04
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023