A Comparative Study on Performance of Two Aerobic Sequencing Batch Reactors with Flocculated and Granulated Sludge Treating an Industrial Estate Wastewater: Process Analysis and Modeling

نویسندگان

  • Nasrin Rezaie Department of Organic Chemistry, Faculty of Chemistry, Razi University, Kermansha
  • SETHUPATHI SUMATHI Department of Environmental Engineering, Faculty of Engineering and Green Technology Univer
  • Somayeh Kiani Water and Environment Division, Water and Power Industry Institute for Applied and
چکیده مقاله:

In this study, the performance of two aerobic sequencing batch reactors (SBR) in removing carbon and nutrient (N & P) from Faraman’s industrial estate wastewater (FIW) with flocculated and granulated sludge were compared. The comparison study was performed by varying two significant independent variables (aeration time and mixed liquor volatile suspended solids (MLVSS)). The experiments were conducted based on a central composite design and analyzed using response surface methodology (RSM). The region of exploration for the process was taken as the area enclosed by aeration time (6-24 h) and MLVSS (2000-7000 mg/L) boundaries. The results showed that the granulated sludge system was more efficient than the flocculated sludge system in removing the non- biodegradable COD (nbCOD), total nitrogen (TN), total phosphorus (TP) and other sludge characteristics studied. The performance of both systems was almost the same for COD removal in FIW with a maximum removal of about 70 %.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of intermittently aerated up-flow sludge bed reactor and sequencing batch reactor treating industrial estate wastewater: a comparative study.

In this study, an innovative aerobic/anoxic sludge bed bioreactor with two feeding regimes, continuous-fed (an up-flow sludge bed reactor (USBR)) and batch fed (sequencing batch reactor (SBR)), was evaluated for the treatment of an industrial estate wastewater with low BOD(5)/COD ratio. The process performance in the two regimes was compared. Two numerical independent variables (retention/react...

متن کامل

performance of biological system and advanced oxidation processes (aop) treating antibiotic production industrial wastewater

در این مطالعه، عملکرد دو سیستم اکسیداسیون شیمیایی پیشرفته و یک سیستم بیولوژیکی برای حذف آموکسی سیلین در فاضلاب های سنتزیدر غلظت های مشابه با موارد صنعتی مورد بررسی قرار گرفته شدند. مطالعه انجام شده دارای سه بخش متفاوت اکسیداسیون با ازن و اشعه uv، اکسیداسیون با استفاده از نانو فتوکاتالیست tio2 و استفاده از بیوراکتور هوازی لجن فعال با جداکننده های فیزیکی می باشد. در هر بخش، متغیر های متفاوتی متنا...

15 صفحه اول

Dynamic Performance Analysis and Simulation of a Full Scale Activated Sludge System Treating an Industrial Wastewater Using Artificial Neural Network

Due to changeable nature of the industrial wastewaters, proper operation of an industrial wastewater treatment plant is of prior importance in order to keep the process stability at the desired conditions. In this mean, simulation of the treatment system behavior using artificial neural network (ANN) can be an effective tool.  This paper evaluates long term performance and process stability of ...

متن کامل

transference of imagery: a comparative formalistic study of shakespeares hamlet and its two persian translations

هدف از این تحقیق بررسی انتقال صور خیال هملت در دو ترجمه ی فارسی آن از نظر فرمالیستی بود. برای بدست آوردن داده-های مورد نیاز، 130 نمونه استعاره، مجاز، ایهام، کنایه و پارادوکس در متن اصلی مشخص شده و سپس بر اساس مدل نیومارک (1998) برای ترجمه ی استعاره یا بطور کلی زبان مجاز با معادل های فارسی شان مقایسه گردیدند. این تحقیق بر آن بود تا روش های استفاده شده برای ترجمه هر کدام از انواع زبان مجاز ذکر شد...

15 صفحه اول

Sequencing Batch Reactor Operation for Treating Wastewater with Aerobic Granular Sludge

In this work, the performance of a sequencing batch reactor (SBR) on aerobic granular sludge was studied for urban wastewater treatment. The system was inoculated with aerobic activated sludge collected from a wastewater treatment plant and, after 30 days of operation, the first granules observed had an average diameter of 0.1 mm. The biomass concentration reached a maximum value around 4 g VSS...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 26  شماره 2

صفحات  105- 116

تاریخ انتشار 2013-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023