Background & Aim: The most important physical quantity of irradiation to predict and evaluate the response of biological samples to irradiation is absorbed dose. Recently, according to ICRU(International Commission on Radiation Units and Measurements) reports, determination of absorbed dose with 3.5% accuracy is recommended. Dose distribution is usually estimated in homogeneous mass by unit density, while irradiated volume consists of different layers such as fat, bones, etc that cause changes in dose distribution. Absorbed dose determination with maximum accuracy is essential for crucial tissues when they are located in body cavities, encircled with heterogeneities(doubted charged particle equilibrium) and when the low quality beams are used in radiobiological studies. The goal of this study is to determine absorbed dose in such situations — rat’s spinal cord. Material & Method: In order to investigate the effect of heterogeneity on the received dose of orthovoltage x-rays in the cervical spinal cord region of rat, a homogeneous phantom of polyethylene, a frozen sample of the animal using liquid nitrogen, and a jig for the reproducibility of the sample were designed and made. The used dosimeter in the project was rod shaped TLD(Thermduminscence Dosimetry) chips, TLD-100. The x-ray generating device was a radiotherapeutic x-ray in potential of 200 Kv(HVL: Half Value Layer=1.5mmCu). The reader device used was Hardshaw TLD reader model 3500 with the heating accuracy of ±1˚C. We took advantage of various dosimetry protocols including American association of physical medicine(AAPM) report TG-61, 2001, dosimetry protocol in radiobiology by Zoteliefe et al, 2001, NSC-report 3, TR-IAEA, 277 protocol and also reports by ICRU-23, 24, 30, 48. Results: Statistical calculations using SPSS for running t-test on the resulting doses within the recommended limit of 3.5%(P<0.001) showed no significant difference between the two groups. Conclusion: Thus, in usual fields in radiobiological studies and within the spectrum of orthovoltage energies used for rats and smaller animals, normal accuracy in calculations could be accepted. However, in the regions where there is no equilibrium in the charged particle and where microdosimetry is concerned the results are not to be crucially applied.
منابع مشابه
اثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملاثر بربرین در تنظیم آستروسیتهای Gfap+ ناحیه هیپوکمپ موشهای صحرایی دیابتی شده با استرپتوزوتوسین
Background: Diabetes mellitus increases the risk of central nervous system (CNS) disorders such as stroke, seizures, dementia, and cognitive impairment. Berberine, a natural isoquinolne alkaloid, is reported to exhibit beneficial effect in various neurodegenerative and neuropsychiatric disorders. Moreover astrocytes are proving critical for normal CNS function, and alterations in their activity...
متن کاملدزیمتری، کنترل و پرتودهی نخاع گردنی موش صحرایی
سابقه و هدف: در رادیوبیولوژی مهمترین عامل فیزیکی تعیین دقیق دز جذبی است. هدف از این پروژه ایجاد چینش مناسب جهت پرتودهی نخاع گردنی موش صحرایی (رت) و دزیمتری آن می باشد. مواد و روش ها: در این مطالعه از پروتکل AAPM TG61 برای اندازه گیری دز جذبی پرتوایکس و بمنظور تضمین و اصلاح دز جذبی از فانتوم استفاده شد. اتاقک یونیزان در این اندازه گیری از نوع فارمر و ماشین مولد پرتو از نوع تیوپ اشعه X پرتودرمانی...
متن کاملاثر وابسته به دوز تجویز تیموکینون بر میزان استرس اکسیداتیو در بافت کلیه موش صحرایی دیابتی
Background and Objective: Due to important role of enhanced oxidative stress in development of renal disorder in diabetes and with regard to antidiabetic and antioxidant effect of thymoquinone, this study was conducted to evaluate the effect of its administration on renal tissue level of some markers of oxidative stress in diabetic rats. Materials and Methods: In this experimental study, Wistar...
متن کاملدزیمتری، کنترل و پرتودهی نخاع گردنی موش صحرایی
سابقه و هدف: در رادیوبیولوژی مهمترین عامل فیزیکی تعیین دقیق دز جذبی است. هدف از این پروژه ایجاد چینش مناسب جهت پرتودهی نخاع گردنی موش صحرایی (رت) و دزیمتری آن می باشد. مواد و روش ها: در این مطالعه از پروتکل aapm tg61 برای اندازه گیری دز جذبی پرتوایکس و بمنظور تضمین و اصلاح دز جذبی از فانتوم استفاده شد. اتاقک یونیزان در این اندازه گیری از نوع فارمر و ماشین مولد پرتو از نوع تیوپ اشعه x پرتودرمانی...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 12 شماره 49
صفحات 53- 62
تاریخ انتشار 2006-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023