بررسی اثر استریلیزاسیون خشک و مرطوب بر سایش لیگاچرکاترهای ارتودنتیک
نویسندگان
چکیده مقاله:
Background and Aim: Orthodontic ligature cutting pliers are expensive. Methods of sterilization should be safe considering patients' health as well as lifetime of orthodontic pliers. The purpose of this study was to compare the wear of orthodontic ligature cutting pliers after sterilizing with dry heat or steam autoclave. Materials and Methods: In this experimental study, thirty ligature cutting pliers from 3 different factories (Dentarum-Germany, RMO and ETM-USA) were sterilized in either dry heat or steam autoclave. The amount of wear at the tip of each plier in both groups was measured with a stereomicroscope and digital photomicrography. Wear was defined as the difference of the initial length and the length after 10, 20, 30 cycles of sterilization measured by the distance from a reference line on the tip of the plier. Three way ANOVA was used to compare wear between the two sterilization groups. P<0.05 was considered as the limit of significance. Results: The amount of wear of the ligature cutting pliers' tip after 10, 20 and 30 cycles in dry heat sterilization was 1.0±0.16, 0.98±0.22 and 0.94±0.31 mm respectively. These figures were 1.16±0.15, 1.16±0.13 and 1.15±0.14mm for steam heat sterilization. The higest wear was observed after 20 cycles of sterilization in autoclavce whereas the lowest was seen in dry heat sterilization after 30 cycles. The differences between the two studied groups were statistically significant (P<0.0001). In addition, increasing sterilization cycles decreased the rate of wear in both groups. Conclusion: Based on the results of this study routine autoclaving caused more damage and wear at the tip of the pliers than dry heat sterilization.
منابع مشابه
بررسی ریزساختار و مقاومت به سایش خراشان خشک و مرطوب لایه روکش سخت پایه Fe-C-B بر روی فولاد ساده کربنی
متن کامل
مقایسه تأثیر پانسمان خشک و مرطوب بر بهبودی زخم سوختگی
Background & Aims: Consistent with recent scientific advances in wound treatment , modern dressing, using technology and knowledge were designed and produced . Such a dressing can provide an appropriate environment for moisturizing wound healing by maintaining and controlling moisture along with other conditions. This study aims to compare the effect of dry and moist dressing on burn wound he...
متن کاملمقایسه تأثیر وضعیت طاق باز و دمر بر وضعیت تنفسی نوزادان نارس مبتلا به سندرم دیسترس تنفسی حاد تحت درمان با پروتکل Insure
کچ ی هد پ ی ش مز ی هن ه و فد : ساسا د مردنس رد نامرد ي سفنت سرتس ي ظنت نادازون داح ي سکا لدابت م ي و نژ د ي سکا ي د هدوب نبرک تسا طسوت هک کبس اـه ي ناـمرد ي فلتخم ي هلمجزا لکتورپ INSURE ماجنا م ي دوش ا اذل . ي هعلاطم ن فدهاب اقم ي هس عضو ي ت اه ي ندب ي عضو رب رمد و زاب قاط ي سفنت ت ي هـب لاتـبم سراـن نادازون ردنس د م ي سفنت سرتس ي لکتورپ اب نامرد تحت داح INSURE ماجنا درگ ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 19 شماره None
صفحات 63- 70
تاریخ انتشار 2006-05
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023