[ 1 ] - Evaluating the Effects of Field Size on Beam Homogeneity Coefficient in the Superficial Radiotherapy Machine Using Empirical Method and Simulation
Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the s...
[ 2 ] - ارزیابی ویژگیهای کیفیت دسته پرتو X دستگاه رادیوتراپی سطحی با روش تجربی و شبیه سازی
One of the most common methods used in radiation therapy for the treatment of superficial skin lesions using the ortho-voltage radiation X (the kVp 300), respectively. One of the most important indicators for the treatment of this type of device, the quality of the X-ray output is usually half the thickness of the absorption (HVL) Vanrzhy show photons effective. However, in this study, the coef...
[ 3 ] - Combined Effects of 528 Hz Sound and X-ray in Peripheral Blood Lymphocytes
Introduction: Radiotherapy is still one of the main options for cancer treatment but it is in association with damage to normal cells as well as the tumor cells. To reduce the injury in normal cells we have evaluated the effect of 528 hertz sound after X irradiation in peripheral blood lymphocytes. Materials and Methods: in this study, peripheral blood was o...
[ 4 ] - Developing a mobile application for usual calculations of radiotherapy physics
Introduction: Successful radiotherapy requires the precise application of a radiation dose to cancerous tissue, which can be achieved by the design of proper treatment methods by radiotherapy physicists. Tasks performed by radiotherapy physicists include verifying the accuracy of dose calculations, correct treatment planning and the proper functioning of accelerators. They are...
[ 5 ] - Iterative Approach for Automatic Beam Angle Selection in Intensity Modulated Radiation Therapy Planning
Introduction: Beam-angle optimization (BAO) is a computationally intensive problem for a number of reasons. First, the search space of the solutions is huge, requiring enumeration of all possible beam orientation combinations. For example, when choosing 4 angles out of 36 candidate beam angles, C36 = 58905 possible combinations exist. Second, any change in a beam 4 config...
[ 6 ] - Effects of Arbutin on Radiation-Induced Micronuclei in Mice Bone Marrow Cells and Its Definite Dose Reduction Factor
Introduction: Interactions of free radicals from ionizing radiation with DNA can induce DNA damage and lead to mutagenesis and carsinogenesis. With respect to radiation damage to human, it is important to protect humans from side effects induced by ionizing radiation. In the present study,the effects of arbutin were investigated by using the micronucleus test for anti- clastog...
[ 7 ] - The microscopic dose enhancement factor measurment of bismuth nanoparticles in external radiation therapy using MRI polymer gel dosimetery
Introduction: Bismuth-based nanoparticles having high atomic number and electron density, besides of being utilized as CT contrast agent, stand as a strongly proposed method for dose enhancement in radiotherapy. Embedded nanoparticle in polymer gel dosimeter poses the first step to assess the dose enhancement capability in nanoparticles. To this end, MAGICA gel dosimeter, whic...
[ 8 ] - The comparison between 6 MV Primus LINAC simulation output using EGSnrc and commissioning data
Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...
[ 9 ] - Image Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
[ 10 ] - Synthesized Gd2O3 nanoparticles as contrast agent
Introduction: Gd (III) ion has been known to be the best metal ion in the periodic table that can be used as a T1 MRI contrast agent. Gadolinium have 7 unpaired electrons and these electrons can make magnetic area. No other metal ions possess unpaired electron more than this. CAs based on the element Gd are classified as “positive”, by opposition to “negative” CAs. Nowadays, G...
[ 11 ] - The protective effects of melatonin on blood cells of rectal cancer patients following radiation therapy; a randomized controlled trial
Introduction: Rectal cancer is a heterozygous disease in which cancerous cells grow in the rectum and lower parts of the colon. The primary cause of this cancer is not yet known, but factors such as over age 50, smoking, family history, improper diet or having a history of polyps and inflammatory bowel disease are the major risk factors for developing the rectum cancer. The rec...
[ 12 ] - Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran
Background:The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate. Â Objective: The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the...
[ 13 ] - Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
[ 14 ] - Calculation of gel dose after external radiation therapy using optical CT
In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...