The microscopic dose enhancement factor measurment of bismuth nanoparticles in external radiation therapy using MRI polymer gel dosimetery

Authors

  • Ali Shabestani Monfared Professor of Medical Physics, Radiotherapy Physicist, Babolsar Oncology Hospital, Department of Medical Physics, Babol Univetsity of Medical Sciences, Babol, Iran.
  • Mehdi Khobi Associate professor of chemistry, Department of Medicinal Chemistry, Faculty of Pharmacy and Pharmaceutical Sciences Research Center, Tehran University of Medical Sciences, Tehran, Iran.
  • Nader Riahi Alam Professor of Medical Physics, Department of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran.
  • Shiva Shoobkolaei Msc of Medical Physics, Department of Medical Physics, Tehran University of Medical Sciences, Tehran, Iran.
Abstract:

Introduction: Bismuth-based nanoparticles having high atomic number and electron density, besides of being utilized as CT contrast agent, stand as a strongly proposed method for dose enhancement in radiotherapy. Embedded nanoparticle in polymer gel dosimeter poses the first step to assess the dose enhancement capability in nanoparticles. To this end, MAGICA gel dosimeter, which is a modified kind of agarose-added magic gel to obtain more stiffness and stability is appropriate method. This study aims at determining the dose enhancement capability of bismuth nanoparticles in this gel under conventional external radiotherapy. Materials and Methods: In current study, the synthesized bismuth nanoparticles approximately with 20 nanometers in diameter and 0.1mM in concentration were injected into MAGICA gel and exposed to 6 MV X-rays beams from linear accelerator simultaneously with control gel samples irradiated in different five doses from 2-10Gy. Results: MAGICA polymer gel response against radiation was characterized by comparing R2 in samples lacking nanoparticles and with Bi-NPs. MAGICA response was found to be linear over the entire dose range explored from 2Gy up to 10 Gy. Results indicated the average dose enhancement factor around 9.8% ± 0.02 in the presence of Bi-NPs. Conclusion: This study investigated the dose enhancement capability of bismuth nanoparticles in external radiotherapy. As well as, MAGICA polymer gel combined with Bi-NPs was approved as a suitable tool for measuring the enhancement of radiation.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Gel dosimetry: The effect of gold nanoparticles on the dose enhancement in the external radiation therapy

Background: Normoxic type MAGICA gel dosimeters are established for dose quantification in three dimensions for radiotherapy. Objective(s): The ability of MAGICA polymer gel was assessed by experimental measurements method for studying the effect of gold nanoparticles (GNPs) in dose enhancement under the external 18MV radiotherapy practices. <...

full text

Dose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...

full text

dose enhancement effect of gold nanoparticles on magica polymer gel in mega voltage radiation therapy

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study...

full text

Investigation of the dose enhancement effect of spherical bismuth oxide nanoparticles in external beam radiotherapy

Introduction: External radiotherapy is the most common method of radiotherapy which the most important problem associated with is that there is no difference between healthy and tumor tissues in dose absorption. One way to differentiate the dose sensitivity is to use metal-based nanoparticles. Bismuth oxide nanoparticles are good candidates for cancer radiotherapy. In this study, we investigate...

full text

Calculation of gel dose after external radiation therapy using optical CT

In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...

full text

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 15  issue Special Issue-12th. Iranian Congress of Medical Physics

pages  329- 329

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023