Validity of Selected WBC Differentiation Flags in Sysmex XT-1800i

Authors

  • Alireza Abdollahi Dept. of Pathology ,Imam Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran | Thrombosis Hemostasis Research Center, Tehran University of Medical Sciences, Tehran, Iran
  • Amirhossein Emami Dept. of Internal Medicine, Tehran University of Medical Sciences, Tehran, Iran
  • Fatemeh Mahjoub Dept. of Pathology, Tehran University of Medical Sciences, Tehran. Iran
Abstract:

Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC diff flags in Sysmex XT-1800i. In addition, we verified the correlation between manual and automated samples. Methods: Overall, 1095 flagged samples were selected in the period of 6 weeks (Imam Hospital complex, Tehran Iran, 2014). The results of both automated and manual counting of the samples were carefully studied and compared. Totally, 624 NRBC flags, 450 Blast flags, 155 abnormal WBC Scatter gram flags, 140 Eosinophilia flags and 468 Monocytosis flags were identified. Results: Considering NRBC and blast flags there was a significant difference between our manual counted and automated counted NRBCs and blasts (P<0.05). There was no significant difference between automated and manual counting of flags for WBC Scatter gram. A significant difference between automated and manual counting data in flags, eosinophilia and monocytosis was foun (P<0.05). Conclusion: We propose the NRBC flags to be ignored and report negative except for the neonatal ward, and the Blasts flags to be ignored and report negative in all the cases. The WBC Scatter gram should be report positive. For eosinophilia and monocytosis flags, we propose, the Sysmex results should be considered correct and the manual checking would not be necessary.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

validity of selected wbc differentiation flags in sysmex xt-1800i

background: automatic cell counter devises make the cbc differential very easy and delivering the results in few second. however, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. in this study, we calculated the validity of wbc diff flags in sysmex xt-180...

full text

Performance characteristics of the Sysmex XT-2000i hematology analyzer.

The XT-2000i is a new hematology analyzer combining aperture impedance and optical technologies. It is capable of generating a 30-parameter hematologic assay on peripheral blood at a throughput of 80 samples per hour. We have evaluated the performance characteristics of the XT-2000i analyzer and compared them with those of the state-of-the-art XE-2100 analyzer and the manual differential count....

full text

Optimized gating and reference ranges of reticulated platelets in dogs for the Sysmex XT-2000iV

BACKGROUND Canine reticulated platelets (r-PLTs) i.e., juvenile PLTs reflecting thrombopoiesis can be measured automatically with the hematology analyzer Sysmex XT-2000iV using manual gating options. However, the impact of interferences on r-PLT measurements performed with the gates published previously (Pankraz et al., Vet Clin Path 38:30-38, 2009; Gelain et al., High fluorescent platelets fra...

full text

The performance of BD FACSPresto™ for CD4 T-cell count, CD4% and hemoglobin concentration test in Ethiopia

INTRODUCTION In Ethiopia, CD4+ T-cell counting is still required for all patients at baseline before antiretroviral therapy (ART) and to determine eligibility and follow-up of opportunistic infection prophylaxis. However, access to CD4+ T cell count in rural health facilities remains a major challenge in Ethiopia like other resource-limited settings. METHODOLOGY Both capillary and venous bloo...

full text

Evaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte

Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...

full text

Biochemical characterization of the adhesion-related differentiation antigen XT-1.

The XT-1-molecule, an adhesion-related differentiation antigen of male mouse germ cells, is a 34 000 Mr glycoprotein with major charge isomer at pI 5.1 and is an integral component of the cell membrane. On large late pachytene spermatocyte, the molecule is present at a concentration of 2.5 X 10(3) molecules micron-2, which approximates HLA/ABC concentration on lymphocytes. By comparing the reac...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 11  issue 2

pages  97- 103

publication date 2016-04-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023