Use of locking plate in combination with dynamic compression plate for repair of tibial fracture in a young horse

Authors

  • - Amarpal Division of Surgery, ICAR-Indian Veterinary Research Institute, Izatnagar-243 122, Bareilly, Uttar Pradesh, India
  • A. M. Pawde Division of Surgery, ICAR-Indian Veterinary Research Institute, Izatnagar-243 122, Bareilly, Uttar Pradesh, India
  • D. N. Madhu Resident of Veterinary Surgery and Radiology, Division of Surgery, ICAR-Indian Veterinary Research Institute, Izatnagar-243 122, Bareilly, Uttar Pradesh, India
  • H. P. Aithal Training and Education Centre, ICAR-Indian Veterinary Research Institute, Shivajinagar, Pune, Maharashtra, India
  • P. Kinjavdekar Division of Surgery, ICAR-Indian Veterinary Research Institute, Izatnagar-243 122, Bareilly, Uttar Pradesh, India
  • R. A. Ahmad Teaching Veterinary Clinical Service Complex, Sher-e-Kashmir University Agricultural Sciences and Technology Kashmir, Shuhama, Srinagar-190006, Jammu and Kashmir, India
Abstract:

Grade 1 open spiral fracture of left tibia in a 1.5 year-old horse was treated using a combination of 4.5 mm locking compression plate (LCP) and a dynamic compression plate applied in a neutralization manner. The open wound was managed postoperatively by regular dressing and lavage. Radiograph at 24 days post-treatment revealed callus formation and at two months complete bridging callus was observed. At the end of six months complete healing of the fracture with functional recovery of the limb was observed.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Outcome of Minimaly Invasive Plate Osteosynthesis (MIPO) Technique with Locking Compression Plate in Distal Tibial Fracture Management

Background: Distal tibial fractures including tibial pilon present a challenge as to their best method of management due to subcutaneous location of larger portion of tibia, paucity of soft tissue coverage and precarious blood supply of distal leg. MIPO (Minimal invasive plating osteosynthesis) has evolved as a newer concept to treat distal tibial fractures with minimal articular comminution an...

full text

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

full text

Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture

Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...

full text

Minimally invasive plate osteosynthesis with locking compression plate for distal diametaphyseal tibia fracture.

BACKGROUND Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology ...

full text

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

full text

fixation of intertrochanteric fractures: dynamic hip screw versus locking compression plate

conclusions despite the complications of fixation with the dhs device, it remains the most successful for treatment of intertrochanteric fractures. background according to the existing literature, the dynamic hip screw (dhs) is the preferred standard for the treatment of intertrochanteric fractures. however, some surgeons use other devices such as the locking compression plate (lcp). objectives...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 18  issue 2

pages  138- 141

publication date 2017-06-20

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023