UPFC Siting and Sizing in Power Network Using Two Different Evolutionary Algorithm

Authors

  • Shahram Javadi Electrical Engineering Department, I.A.U., Central Tehran Branch, Iran
Abstract:

In emerging electric power systems, increased transactions often lead to the situations where the system no longer remains in secure operating region. The flexible Ac transmission system (FACTS) controllers can play an important role in the power system security enhancement. However, due to high capital investment, it is necessary to locate these controllers optimally in the power system. FACTS devices such as UPFC can regulate the active and reactive power control as well as being adaptive to voltage-magnitude control simultaneously because of their flexibility and fast control characteristics. Placement and sizing these devices in suitable location can lead to control in line flow and maintain bus voltages in desired level and so improve voltage stability margins. Moreover, this adjustment can improve voltage profile system along with reducing the power system losses. This paper proposes a systematic method by which optimal location and sizing of Unified Power Flow Controller (UPFC) to be installed using two different evolutionary algorithm. FACTS DEVICES model is incorporated into a Newton-Raphson algorithm to perform load flow analysis. Optimizing its location becomes a concern when coming to the practical implementation stage. Proposed algorithm is tested on IEEE 24 bus power system for optimal allocation as well as sizing of UPFC device and results are presented.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

upfc siting and sizing in power network using two different evolutionary algorithm

in emerging electric power systems, increased transactions often lead to the situations where the system no longer remains in secure operating region. the flexible ac transmission system (facts) controllers can play an important role in the power system security enhancement. however, due to high capital investment, it is necessary to locate these controllers optimally in the power system. facts...

full text

fault location in power distribution networks using matching algorithm

چکیده رساله/پایان نامه : تاکنون روش‏های متعددی در ارتباط با مکان یابی خطا در شبکه انتقال ارائه شده است. استفاده مستقیم از این روش‏ها در شبکه توزیع به دلایلی همچون وجود انشعاب‏های متعدد، غیر یکنواختی فیدرها (خطوط کابلی، خطوط هوایی، سطح مقطع متفاوت انشعاب ها و تنه اصلی فیدر)، نامتعادلی (عدم جابجا شدگی خطوط، بارهای تک‏فاز و سه فاز)، ثابت نبودن بار و اندازه گیری مقادیر ولتاژ و جریان فقط در ابتدای...

Genetic Algorithm for Optimum Siting and Sizing of Distributed Generation

This paper presents a powerful approach to find the optimal size and location of distributed generation units in a distribution system using Genetic Optimization algorithm (GA). The total active and reactive power losses are minimized and voltage profile is improved. GA fitness function is introduced including the active power losses, reactive power losses and the cumulative voltage deviation v...

full text

analysis of power in the network society

اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...

15 صفحه اول

Optimum Siting and Sizing of Shunt Capacitors in Radial Distribution System using Novel BPSO Algorithm

Consolidation of shunt capacitors plays an important role in radial distribution networks. Among many of their merits, line loss and total harmonic distortion (THD) reduction, voltage profile improvement and reactive power compensation can be the salient specifications of shunt capacitors. Studies show that non-optimal locations shunt capacitor units lead to increase loss, together with bad eff...

full text

Location and Capacity of UPFC to Improve the Operation Power System Using a Grasshopper Optimisation Algorithm

Unified Power Flow Controller (UPFC) is one of the most efficient FACTS devices that can be individually or combinatorial on all effective parameters in the transmission power of the transmission lines. With the flexibility of effective parameters in power passage, the power system operation can be improved. in this study, the optimization algorithm based on location and optimal capacity of UPF...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 05  issue 03

pages  161- 167

publication date 2016-09-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023