Thermoeconomic analysis of a hybrid PVT solar system integrated with double effect absorption chiller for cooling/hydrogen production

Authors

  • Ali Habibollahzade School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
  • Amirmohammad Behzadi School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
  • Ehsan Gholamian School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
  • Ehsan Houshfar School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
  • Mehdi Ashjaee School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
Abstract:

A novel solar-based combined system which is consisting of a concentrated PV, a double effect LiBr-H2O absorption chiller, and a Proton Exchange Membrane (PEM) is proposed for hydrogen production. A portion of the received energy is recovered to run a double effect absorption chiller and the rest is turned into electricity, being consumed in the PEM electrolyzer for hydrogen production. The thermodynamic and thermoeconomic analyses are performed to understand the system performance. A parametric study which is implementing Engineering Equation Solver (EES) is carried out to assess the influence of main decision parameters on the overall exergy efficiency and total product unit cost. The 2nd law analysis shows that PVT with exergy destruction rate of 76.9% of total destruction rate is the major source of irreversibility. Furthermore, in the cooling system, Cooling Set (CS) has the highest exergy destruction rate due to the dissipative components. Exergoeconomic results demonstrate that in cooling set with the lowest value of exergoeconomic factor, the cost of exergy destruction and loss has the major effect on the overall cost rate. Furthermore, results of the parametric study indicate that by decreasing PV cell’s temperature from 100 °C to 160 °C, the total product unit cost is decreased by about 1.94 $/GJ.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Advanced Exergy Analysis for a Solar Double Stage Absorption Chiller

.............................................................................................................................. i List of Figures ................................................................................................................... vi List of Tables .................................................................................................................... i...

full text

Thermoeconomic Analysis of a Single and Double-Effect LiBr/H2O Absorption Refrigeration System*

The aim of this work is to carry out a thermoeconomic analysis of a single and double-effect LiBr/H2O absorption refrigeration system. The methodology of functional analysis with negentropy is used. The exergetic cost of the main product, the cooling cost, was calculated as a function of the exergy of the heat source. Two cases were analyzed for each system: the first considers a direct-fired s...

full text

Thermodynamic and Thermoeconomic Optimization of an Absorption Refrigeration System integrated with Refinery Crude Oil Furnace

In the present study, exhaust gases from Tehran refinery crude oil furnace are used in a Heat Recovery Steam Generator (HRSG)for generating steam. Then, the steam is directed to a double effect absorption refrigeration cycle to produce cooling. To meet the object, mass and energy balance equations of the coupling is carried out for both the HRSG and the absorption chiller and unknown thermodyna...

full text

Solar Cooling System Using Solar-Driven Hybrid Chiller

We developed an appropriate Absorption chiller to "Solar cooling system" in 2010. In addition, we added the improvement to the machine. "Solar cooling system" can be easily constructed with the machine. and, we constructed the demonstration plant, and verified the utility

full text

An Optimized Design of a Single Effect Absorption Solar Chiller for an Energy Consuming Optimized Designed Residential Building

Traditional fossil fuels lead to environmental problems and are also depleting. A significant portion of global energy consumption is due to building’s air conditioning. Nowadays there is a great attention toward renewable and sustainable energy sources to support the buildings energy requirements. In this study, a solar cooling machine was designed for a three-floor residential building under ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 6  issue 4

pages  413- 427

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023