The relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus

Authors

  • Mehdi Khabazkhoob Department of Medical Surgical Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Mohsen Ahadi Department of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran. Address: Shahnazari St, Mirdamad Blvd, Tehran, Iran.
  • Nasrin Yazdani Otorhinolaryngology Research Centre, AmirAlam Hospital, Tehran University of Medical Sciences, Tehran, Iran.
  • Saeid Mahmoudian ENT and Head & Neck Research Center, Iran University of Medical Sciences, Tehran, Iran.
  • Shaghayegh Omidvar Department of Audiology, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran.
  • Zahra Jafari Department of Rehabilitation Basic Science, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran.
Abstract:

  Background: The possible role of cochlear function in tinnitus generation is still a matter of debate. To assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (UHF) hearing sensitivity, transient evoked otoacoustic emissions (TEOAE) and UHF hearing thresholds were investigated in normal hearing individuals with and without tinnitus.   Methods: Eighteen individuals with tinnitus and 22 without tinnitus participated in this study. TEOAE was recorded with click stimulus at 80 dBpeSPL. UHF pure tone audiometry was performed at 10, 12.5, 16, and 18 kHz.   Results: TEOAE was significantly abnormal in 72.2% of the tinnitus, and 18.2% of the control groups (p=0.001). The individuals with tinnitus had significantly poorer UHF hearing sensitivity compared to the control group at 12.5 and 18 kHz (p≤0.048). There was a stronger correlation between increasing UHFs hearing threshold and decreasing SNRs of TEOAEs in the tinnitus group compared to the controls.   Conclusion: Our study revealed poorer UHF hearing thresholds and more TEOAE abnormalities in normal hearing individuals with tinnitus compared to the controls. Perhaps the alterations in the basal cochlea, following a decrease in UHF hearing sensitivity, affect OAEs that are originated from more apical cochlear parts in tinnitus ears more than non-tinnitus ears.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

the relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus

background: the possible role of cochlear function in tinnitus generation is still a matter of debate. to assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (uhf) hearing sensitivity, transient evoked otoacoustic emissions (teoae) and uhf hearing thresholds were investigated in normal hearing individuals with and without tinnitus. ...

full text

Evaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing

Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...

full text

Repeatability of Transient-Evoked Otoacoustic Emissions in Young Adults

BACKGROUND The aim of this study was to evaluate the repeatability and variability of TEOAE characteristics in hearing screening tests performed under practical conditions on normal subjects. MATERIAL/METHODS A group of 11 young, normal-hearing subjects aged 19-24 years was tested. They were examined otologically and audiologically prior to the tests and no ear pathologies were found. Respons...

full text

Transient Evoked Otoacoustic Emissions and High Risk Register in Neonates

The development and application of otoacoustic emissions in clinical practice marked the beginning of a new era in the field of screening for congenital hearing loss. In particular, transient evoked otoacoustic emissions (TEOAEs) have been widely adopted by many universal hearing screening (UNHS) programs. The test is quick, non-invasive, objective, sensitive, frequency specific, relatively che...

full text

High-frequency click-evoked otoacoustic emissions and behavioral thresholds in humans.

Relationships between click-evoked otoacoustic emissions (CEOAEs) and behavioral thresholds have not been explored above 5 kHz due to limitations in CEOAE measurement procedures. New techniques were used to measure behavioral thresholds and CEOAEs up to 16 kHz. A long cylindrical tube of 8 mm diameter, serving as a reflectionless termination, was used to calibrate audiometric stimuli and design...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 30  issue 1

pages  1088- 1098

publication date 2016-01

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com