The Performance of Compost Biofilter for Hydrogen Sulfide Removal from Contaminated Air

author

  • S. A. Shojaosadati and A. Seifi
Abstract:

In order to evaluate the performance of biofilter for H2S removal from contaminated air, a 120×14 cm column biofilter was constructed using clear polyacrylic material in conjunction with H2S production and control systems. The column was divided into four stages using perforated plates. The column was packed with a mixture of mushroom compost and snail shell (4:1).&#10 The performance of biofilter was evaluated during 4 months of operation under various flow rates and H2S concentrations in ambient temperature. According to the results, the removal effeciency of H2S in polluted air for concentrations of up to 150 ppm, average temperature of 26.9°C and under flow rates of 6 and 12 l.min-1 was more than 95% the results for average temperature of 20.5°C and the flow rates of 19.5 and 26 l.min-1 but constant H2S concentration was more than 85%. The maximum removal rate (Vm) was measured as 0.075 g S/kg-dry compost.h and average saturation constant (Ks) was 32.5 ppm&#10

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Removal of Hydrogen Sulfide from Biogas Using Cow-manure Compost

The two-part objective of this study was to determine currently available H2S removal technologies suitable for use with farm biogas systems, and to test the feasibility of utilizing on-farm cow-manure compost as an H2S adsorption medium. Integrated farm energy systems utilize anaerobic digesters to provide a waste treatment solution, improved nutrient recovery, and energy generation potential ...

full text

performance of biofilter for the removal of hydrogen sulphide odour

laboratory scale experiments were performed to evaluate the feasibility of biofilters for the removal of h2 s from wastewater treatment plant waste air. the effects of changes in air flow rate and contaminant concentration on biofilter performance treating h 2 s odours were also assessed. compost was used as media in biofilter. the study was carried out in six different phases, by increasing h2...

full text

Performance of Biofilter for the Removal of Hydrogen Sulphide Odour

Laboratory scale experiments were performed to evaluate the feasibility of biofilters for the removal of H 2 S from wastewater treatment plant waste air. The effects of changes in air flow rate and contaminant concentration on biofilter performance treating H 2 S odours were also assessed. Compost was used as media in biofilter. The study was carried out in six different phases, by increasing H...

full text

Changes in physical properties of a compost biofilter treating hydrogen sulfide.

A technique is presented that can be used to estimate the changes in physical structure in a natural biofilter packing medium, such as compost, over time. The technique applies information from tracer studies, grain size distribution, and pressure drop analysis to a model that estimates the number of channels, average channel diameter, number of particles, and specific surface area of the mediu...

full text

A high-performance adsorbent for hydrogen sulfide removal

Spatially well-distributed copper-zinc oxides supported on mesoporous silica (SBA-15 and commercial silica gel) showed high adsorption capacity for hydrogen sulfide (as high as 80 mgS/gsorbent) and stability during cyclic adsorption-regeneration process. 2014 Elsevier Inc. All rights reserved.

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 20  issue 1

pages  43- 53

publication date 2001-07

By following a journal you will be notified via email when a new issue of this journal is published.

Keywords

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023