The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

Authors

  • Fataneh Nemati Science & Research Branch, Islamic Azad University, Tehran, Iran
  • Mehrdad Gholami Department of Medical Physics & Radiation Sciences, School of Para medicine Sciences, Lorestan University of Medical Sciences, Khorram Abad, Iran
  • Vahid Karami Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
Abstract:

Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation dose. Materials and Methods This cross-sectional study was performed on seven stationary X-ray units in sixhospitals of Lorestan province. The measurements were performed, using a factory-calibrated Barracuda dosimeter (model: SE-43137). Results According to the results, the highest output was obtained in A Hospital (M1 device), ranging from 107×10-3 to 147×10-3 mGy/mAs. The evaluation of tube voltage accuracy showed a deviation from the standard value, which ranged between 0.81% (M1 device) and 17.94% (M2 device) at A Hospital. The deviation ranges at other hospitals were as follows: 0.30-27.52% in B Hospital (the highest in this study), 8.11-20.34% in C Hospital, 1.68-2.58% in D Hospital, 0.90-2.42% in E Hospital and 0.10-1.63% in F Hospital. The evaluation of exposure time accuracy showed that E, C, D and A (M2 device) hospitals complied with the requirements (allowing a deviation of ±5%), whereas A (M1 device), F and B hospitals exceeded the permitted limit. Conclusion The results of this study showed that old X-ray equipments with poor or no maintenance are probably the main sources of reducing radiographic image quality and increasing patient radiation dose.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

the evaluation of conventional x-ray exposure parameters including tube voltage and exposure time in private and governmental hospitals of lorestan province, iran

introduction in radiography, dose and image quality are dependent on radiographic parameters. the problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...

full text

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

full text

Analysis on X-Ray Parameters of Exposure by Measuring X-Ray Tube Voltage and Time of Exposure

---------------------------------------------------------------ABSTRACT-----------------------------------------------------One of the typical human diagnostic techniques is x-ray. The x-ray examination depends on the range of radiation given to the subject. The radiation from the xray depends primarily upon the x-ray tube current (mA) tube voltage (kVp) and exposure time (s). These parameters ...

full text

the survey of the virtual higher education in iran and the ways of its development and improvement

این پژوهش با هدف "بررسی وضعیت موجود آموزش عالی مجازی در ایران و راههای توسعه و ارتقای آن " و با روش توصیفی-تحلیلی و پیمایشی صورت پذیرفته است. بررسی اسنادو مدارک موجود در زمینه آموزش مجازی نشان داد تعداد دانشجویان و مقاطع تحصیلی و رشته محل های دوره های الکترونیکی چندان مطلوب نبوده و از نظر کیفی نیز وضعیت شاخص خدمات آموزشی اساتید و وضعیت شبکه اینترنت در محیط آموزش مجازی نامطلوب است.

phylogeography and genetic diversity of the lesser mouse- eared bat (myotis blythii) in iran

in current study, 63 samples of bat populations collected from differ regions were used for evaluating the geographic variations. twenty cranial and dental characters for traditional morphometric and landmarks method on the ventral, dorsal skull and mandible for geometry morphometric studies were used. statistical analyses of traditional morphometric and geometry morphometric data indicated low...

Radiation exposure of the Yazd population from medical conventional X-ray examinations

Background: Radiation dose knowledge through Xray examinations and their distribution in Iran provides useful guidance on patient dose reduction. The results of the entrance skin dose (ESDs) of five common radiographies in all radiology centers in Yazd province were reported in our previous study (2003). In the present study we have evaluated the collective effective dose of convention...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 12  issue 2

pages  85- 92

publication date 2015-06-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023