The Effect of Different Electrodes on Humic Acid Removal by Electrocoagulation

Authors

  • Bagher Anvaripour Associate Professor, Department of Chemical Engineering (Safety and Technical Protection), Petroleum University of Technology, Abadan, Iran
  • Farhad Asgharyan M.S. Student, Department of Chemical Engineering (Safety and Technical Protection), Petroleum University of Technology, Abadan, Iran
  • Iman Danaee Associate Professor, Department of Technical Inspection Engineering, Petroleum University of Technology, Abadan, Iran
Abstract:

The present study is about the reduction of humic acids (HA) by electrocoagulation (EC) method. Undesirable color, odor, taste, reacting with chlorine to produce toxic materials in water, and making a complex with heavy metal ions are some unfavorable environmental consequences of HA. Platinum and graphite as anode electrodes and platinum, titanium, and aluminum as cathode electrodes were used for this purpose. Also, solutions consisting of sodium sulfate (Na2SO4), as the electrolyte support, and humic acids at a concentration of 30 mg.l-1 were used in the reduction tests. We investigated the best condition for pollutant removal at pH values of 3, 5, and 7 and voltages of 5, 10, and 18. The samples were taken during the electrolysis and were analyzed by the pH meter and UV-visible spectrophotometer. Moreover, the oxidation phenomena on anodes surface were studied by cyclic voltammetry tests. The results confirm that the Gr/Al electrodes by coagulation phenomena shows the best performance in the elimination of HA at an electrolyte support concentration of 0.02 molar after approximately 23 min at a pH of 7 and a voltage equal to 10 V.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Humic acid removal from aqueous solutions by peroxi-electrocoagulation process

Background: Natural organic matter is the cause of many problems associated with water treatment such as the presence of disinfection by-products (DBPs) and membrane fouling during water filtration. In this study, the performance of the peroxi-electrocoagulation process (PEP) was investigated for the removal of humic acids (HAs) from aqueous solutions. Methods: PEP was carried out for the remov...

full text

humic acid removal from aqueous solutions by peroxi-electrocoagulation process

background: natural organic matter is the cause of many problems associated with water treatment such as the presence of disinfection by-products (dbps) and membrane fouling during water filtration. in this study, the performance of the peroxi-electrocoagulation process (pep) was investigated for the removal of humic acids (has) from aqueous solutions. methods: pep was carried out for the remov...

full text

Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes

Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment techn...

full text

the effect of keeping reflective journals by language instructors on the process of reading comprehension among iranian high school students

خواندن ودرک مطلب از مهمترین مهارتها در یادگیری زبان خارجی محسوب می شود. این تحقیق تاثیر برگه های تامل برانگیز هدایت شده را در ارتقاع مهارت خواندن ودر ک مطلب در دانش اموزان دبیرستانی ایرانی بررسی می نماید. ازمجموع ?2 دانش آموز سال چهارم دبیرستان شهید رجایی شهرستان اسلامشهر¸ پس از اجرای آزمون استاندارد ((nelson 150a تعداد 39 دانش آموز که نمرات آنها یک سطح انحراف معیار بالاتر یا پایین تر ازمعدل قر...

Investigation of Phenol Removal by Proxy-Electrocoagulation Process with Iron Electrodes from Aqueous Solutions

Background: Phenol as an aromatic hydroxyl compound are considered as a priority pollutant.  Because of their stability, solubility in water and high toxicity had health important. Methods: In the present experimental study, electrocoagulation reactor by iron electrodes are used in the presence of hydrogen peroxide to phenol removing from aqueous solutions. Effects of variables including ...

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 7  issue 2

pages  52- 63

publication date 2018-04-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023