The Amount of Wear in Attachment of Implant-Supported Overdentures in Mandible

Authors

  • Fariborz Vafaee Associated Professor, Department of Prosthodontics, Dental Research Center, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
  • Farnaz Firuz Assistant Professor, Department of Prosthodontics, Dental Research Center, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
  • Farnoush Fotovat Resident of Prosthodontics, Department of Prosthodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran
  • Ghodratallah Roshanaei Assistant Professor, Department of Biostatistics, Faculty of Health, Hamadan University of Medical Sciences, Hamadan, Iran
  • Hamed Amraei Resident of Prosthodontics, Department of Prosthodontics, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.
  • Masumeh Khoshhal Assistant Professor, Department of Periodontology, Implant Research Center, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.
  • Samira Soufiabadi Assistant Professor, Department of Prosthodontics, Dental Research Center, Faculty of Dentistry, Zahedan University of Medical Sciences, Zahedan, Iran.
Abstract:

Background and objectives: One of the simplest and cheapest attachments for overdentures, is the ball-type attachment, however, keeping it during the first year of prosthesis delivery and after that is one of the main concerns of dentists. The present study aimed to assess the wear of matrix in overdentures attachment supported by one, two and three implants in the mandible. Materials and methods: Thirty edentulous patients were randomly divided into three groups: the first group received a single implant in the midline of the lower mandible, the second group two implants in areas B and D, and the third group three implants in areas B, C, and D. The attachment used in patients’ prosthetic with single and two implants was O-ball/ring attachment and for patients with three implants, the treatment plan was ball bar-supported attachments. After placing the new matrix implant for each patient and obtaining their consent, the matrix wear was measured with CMM (Coordinate Measuring Machine) device. To compare matrix wear after six months and one year, measurements were repeated. Data analysis, using ANOVA and multiple comparisons was down by Tukey Test. variance with repeated measures and Tukey test were used to compare the groups two-by-two. P.value less than 0.05 was set statistical significant. SPSS 16 software was used for data analysis. Results: The data obtained from the CMM device showed that the lowest mean matrix wear in the maximum single implant and maximum mean were in group two. Conclusion: Both time and the number of implants had a significant effect on the wear of the O-ring.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

the amount of wear in attachment of implant-supported overdentures in mandible

background and objectives: one of the simplest and cheapest attachments for overdentures, is the ball-type attachment, however, keeping it during the first year of prosthesis delivery and after that is one of the main concerns of dentists. the present study aimed to assess the wear of matrix in overdentures attachment supported by one, two and three implants in the mandible. materials and metho...

full text

the effect of the record infancy in crimilly acts of guilties (in karaj city)

چکیده یکی از مهمترین دغدغه های بزرگ جوامع بشری، از دیر باز تا کنون که ذهن پژوهشگران و متخصصان بهداشت روانی و اجتماعی و دولتها رابه خود مشغول داشته، مسأله ی بزهکاری می باشد. شناخت کامل پدیده ی بزهکاری و بزهکار، علل وعوامل سقوط یک انسان، چگونگی درمان وی و درنهایت پیشگیری ازبزهکاری ودریک کلام سالم سازی یک جامعه، رسالت عظیم، انسانی ومقدسی می باشد که با بررسی شخصیت مجرم یعنی[ انسانی که تحت شرای...

15 صفحه اول

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

full text

analysis of power in the network society

اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...

15 صفحه اول

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 5  issue 4

pages  181- 188

publication date 2016-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023