Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Authors

  • Foad Sadi Department Clinical Sciences Faculty of Veterinary Medicine, Mahabad Branch, Islamic Azad University, Mahabad, Iran
  • Siamak Alizadeh Department of Clinical Sciences, Faculty of Veterinary Medicine, Urmia Branch, Islamic Azad University, Urmia, Iran
Abstract:

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-day intervals by the same observer. Mitral, tricuspid, aortic and pulmonary flows were measured from a right parasternal view, and mitral and aortic flows were also measured from a left parasternal view. The difference between left and right side measurements and the intraobserver inter-day repeatability were tested and then the reference values of PW Doppler echocardiographic parameters in healthy adult female Markhoz goals were established.Results- As documented in other species, all caprine PW Doppler parameters demonstrated a poor inter-day repeatability and a moderate variability. Tricuspid and pulmonary flows were best evaluated on the right side whereas mitral and aortic flows were best obtained on the left side, and reference values are reported for healthy adult Markhoz goats.Conclusions- PW Doppler echocardiography allows the measurement of intracardiac blood flow indices in goats. The reference values establishment will help interpreting these indices of cardiac function in clinical cardiac cases and developing animal models for human cardiology research.

Upgrade to premium to download articles

Sign up to access the full text

Already have an account?login

similar resources

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

full text

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

full text

normal left ventricular systolic time intervals assessed by pulsed wave doppler echocardiography in the turkmen horse of iran

the turkmen horse is one of the oldest and purest breeds in the world. there is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. pulsed-wave (pw) doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing turkmen horses. there were 26 stallions and 16 mares. the left ventricular isovolumetric contrac...

full text

Pulsed Wave Doppler and Color Flow Doppler Evaluation in Healthy Dogs and Dogs with Cardiac Disease

Doppler echocardiography gives a physiological assessment of blood flow within the cardiac chambers, across valve orifices and in the great vessels. Pulsed wave Doppler can detect flow pattern in a very discrete region of simultaneously imaged 2-D echocardiographic plane. Twenty apparently healthy dogs and twenty affected dogs with dilated cardiomyopathy and mitral valve insufficiency ten each ...

full text

normal pulsed wave doppler echocardiographic parameters of turkmen horses of iran

turkmen horse is one of the oldest and purest breeds in the world, but there is no information on doppler echocardiographic parameters in this horse. in the present study, pulsed-wave (pw) doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing turkmen horses. no cardiac disease was detected with two-dimensional (2-d) real-time, m-mode, and colour flow mapping. d...

full text

Age-related valvular regurgitation: a study by pulsed Doppler echocardiography.

To assess the prevalence of valvular regurgitation in the aged, we studied 176 apparently healthy volunteers with no history or physical evidence of cardiac abnormality. Their ages ranged from 40 to 90 (66 +/- 14, mean +/- SD) years. We examined these subjects by pulsed Doppler echocardiography combined with two-dimensional echocardiography to determine the prevalence of valvular regurgitation....

full text

My Resources

Save resource for easier access later

Save to my library Already added to my library

{@ msg_add @}


Journal title

volume 13  issue 2

pages  1- 7

publication date 2018-12-01

By following a journal you will be notified via email when a new issue of this journal is published.

Hosted on Doprax cloud platform doprax.com

copyright © 2015-2023